XAG P100/P100 Pro Motor & ESC Mandatory
Maintenance Instructions
While the XAG P100/P100 Pro aircraft is operating, it would experience vibrations that
might cause the screws securing the Motor connector and ESC to loosen, potentially
causing a disconnection of power. The wear and tear of the isolators could have
prompted the melting due to heat during the operation. Such an event could trigger an
electrical surge and excessive heat production, possibly resulting in the Motor/ESC
failure.
1. Loosen the four screws securing the red bumper and then detach the bumper.