EasyManuals Logo

XAG P100 Instruction Manual

XAG P100
5 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
XAG Australia
ABN 56 614 943 118
Unit 5, 11 Jullian Cl.
Banksmeadow NSW 2019
P. +61 (2) 9168 7918
E. info@xagaustralia.com.au
www.xagaustralia.com.au
XAG P100 2022 MAINTENANCE INSTRUCTION & NOTICE - 28/10/2022
When the XAG P100 RPA is operating under load during the flight, the flight vibration may cause the
screws joining the motor connector and insulator hub assembly to become loose. The spacing between
the connector and insulator may cause a short circuit resulting in a power surge and excessive heat
generated. The result may include melting deformation of the plastic Hub/Assembly.
Mandatory Maintenance Schedule Manufacturer Maintenance Advice
Instructions on how to check and maintain the motor connectors/hub assembly are as follows:
01 Unscrew the four screws that tightened the red bumper/navigation light and then remove the
bumper.

Other manuals for XAG P100

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the XAG P100 and is the answer not in the manual?

XAG P100 Specifications

General IconGeneral
BrandXAG
ModelP100
CategoryDrones
LanguageEnglish

Related product manuals