Xantrex XKW 40-25 Specifications

General IconGeneral
BrandXantrex
ModelXKW 40-25
CategoryPower Supply
LanguageEnglish

Summary

Limited Warranty

What does this warranty cover and how long does it last?

Details warranty coverage duration and scope for the DC Power Supply.

What will Xantrex do?

Explains Xantrex's obligations for repair or replacement under warranty.

How do you get service?

Provides contact information for obtaining warranty service and support.

Disclaimer Product

Exclusions

Lists conditions and damages not covered by the limited warranty.

Warnings and Cautions

Power Supply Safety

Defines safety symbols and provides critical safety instructions for power supply operation.

About This Manual

Main Sections

Outlines the structure and content of the operating manual, describing key sections.

Features and Specifications

Description

Introduces the XKW Series power supplies, highlighting their capabilities and technology.

Features and Options

Lists key features and optional capabilities of the XKW Series power supplies.

Front Panel Controls

Describes the controls, indicators, and displays located on the front panel.

Rear Panel Connectors and Switch

Details the connectors and internal switch located on the rear panel of the power supply.

Controls, Connectors, and Indicators

Provides an overview of various controls, connectors, and indicators on the unit.

Specifications

Presents detailed electrical specifications for the XKW Series power supply models.

Additional Specifications

Lists further specifications including rise time, fall time, and transient response.

Input Conditions

Outlines the required input voltage, current, frequency, and power factor.

Additional Features

Describes features like switching frequency, hold-up time, and insulation resistance.

Remote Programming and Monitoring

Explains remote start/stop, interlock, monitoring, and compensation capabilities.

Environmental Specification

Details operating and storage temperature, humidity, and altitude requirements.

Mechanical Specifications

Covers physical dimensions, weight, connector types, and approvals.

Installation

Introduction

Provides guidance on inspecting, installing, and testing the power supply.

Basic Setup Procedure

Summarizes the essential steps for setting up the power supply.

Inspection, Cleaning, and Packaging

Details initial inspection procedures and methods for periodic cleaning.

Returning Power Supplies to the Manufacturer

Outlines the policy and procedure for returning units for service or repair.

Packaging for Shipping or Storage

Provides instructions for safely packaging the unit for shipping or storage.

Location, Mounting and Ventilation

Guides on proper placement, mounting in racks, and ensuring adequate ventilation.

AC Input Power

Covers connecting AC power and selecting the correct input voltage.

Functional Tests

Describes procedures for performing functional tests on the power supply.

Voltage Mode Operation

Explains how to check and verify voltage mode operation.

Current Mode Operation

Details the steps to check and verify current mode operation.

Load Connection

Provides guidance on connecting the load and ensuring stable, low-noise output.

Load Conductor Ratings

Shows current carrying capacity for various wire gauges used in load wiring.

Output Cord Strain Relief

Explains how to assemble and attach the strain relief for the DC output connector.

Local and Remote Sensing

Describes the use and connection of local and remote sensing for regulation.

Operation

Single Supply Operation (Local Mode)

Guides on operating a single power supply using front panel controls.

Multiple Supplies

Discusses operating multiple units in series, parallel, or split configurations.

Series Operation

Explains how to connect units in series for higher voltage output.

Parallel Operation

Details how to connect units in parallel for higher current output.

Split Supply Operation

Describes obtaining dual positive or positive-negative outputs.

Over Voltage Protection (OVP)

Explains the OVP circuit function, activation, and reset procedures.

Front Panel OVP Operation

Provides steps to set the OVP trip level using the front panel potentiometer.

Remote Programming of OVP With External Voltage Sources

Details how to remotely program OVP using a 0-5V or 0-10V voltage source.

Remote Programming of OVP with an External Resistance

Explains how to remotely program OVP using a 5k ohm external potentiometer.

Remote Programming of OVP with External Current Sources

Details programming OVP using a 0-1mA current source.

Remote OVP Sensing

Describes shifting the OVP sensing point from the output terminals to the sense lines.

Remote ON/OFF

Explains how to remotely control the power supply output using TTL or AC/DC inputs.

Remote ON/OFF by Contact Closure

Details using an external relay for remote ON/OFF control via contact closure.

Remote Programming of Output Voltage and Current Limit

Introduces remote programming of output voltage and current limit via J3 connector.

Remote Programming Switch SW1

Explains the functions of switch SW1 for controlling programming scales and modes.

Programming With External Voltage Sources

Details programming output voltage using external 0-5Vdc and 0-10Vdc sources.

Programming With an External Resistance

Explains how to program output current limit using a 5k ohm potentiometer.

Programming With an External Current Source

Details programming output voltage and current limit using a 0-1mA current source.

Remote Monitoring and Status Indicators

Describes readback signals for voltage/current and status indicators available via J3.

Using Over Temperature Protection (OTP)

Explains the OTP circuit and how to reset it after a shutdown.

Calibration

Introduction

Introduces the calibration process and safety precautions.

Calibration Setup

Guides on setting up the environment and tools for calibration.

Service Environment and Precautions

Lists essential safety practices and environmental considerations for calibration.

Calibrating

Details the trimpot designations and parameters affected during calibration.