Xantrex XPH 35-4D Specifications

General IconGeneral
ModelXPH 35-4D
Output Current0-4 A
Power140 W
Frequency50/60 Hz
Output Voltage0-35 V
Operating Temperature0 to 40°C
ProtectionsShort Circuit
Weight6.8 lbs (3.1 kg)

Summary

Introduction

Specification Overview

Meter Specifications

Auxiliary Logic Output Specs

General Specifications

EMC Compliance

Emissions and Immunity Standards

Details electromagnetic emissions, immunity test limits, and performance criteria.

EMC Cautions

Provides precautions for maintaining EMC compliance.

Safety Information

General Safety Precautions

Important warnings and guidelines for safe operation and handling.

Operational Symbols

Explanation of safety and operational symbols found in the manual and on the unit.

Installation and Connections

Mains Lead Connection

Guidance on correctly connecting the mains power lead.

Load and Ground Connections

How to connect the load to output terminals and chassis ground.

Operation - Main Outputs

Setting Up Main Outputs

Procedure for presetting voltage and current limits before activation.

Main Output Modes and Protection

Explains CV/CC modes and built-in protection features.

Operation - Auxiliary Output

Auxiliary Output Settings

How to set voltage and current limit for the auxiliary output.

General Operation

Series/Parallel Connections and Ventilation

Guidelines for connecting outputs and maintaining airflow.

Calibration Procedures

Calibration Access and Equipment

How to access calibration points and required test equipment.

Voltage Calibration

Step-by-step instructions for calibrating voltage output.

Current Calibration

Voltage Regulation Calibration

1.5V/5V Output Calibration

Maintenance

Fuse Replacement and Cleaning

Instructions for fuse replacement and safe cleaning procedures.

Warranty Information

Obtaining Service and Returns

Instructions for contacting Xantrex for support, warranty, and return procedures.

Warranty Exclusions and Limitations

Disclaimer and Usage Warnings

Return Material Authorization Policy

Return Procedure and Out-of-Warranty Service

Step-by-step guide for returns and information on out-of-warranty service.