Model | XKW 80-13 |
---|---|
Output Current | 80 A |
Input Frequency | 47-63 Hz |
Efficiency | >85% |
Operating Temperature | 0°C to 40°C |
Storage Temperature | -20°C to 70°C |
Protection Features | Over Voltage, Over Current, Over Temperature, Short Circuit |
Cooling Method | Forced Air |
Output Voltage | 13.8V |
Lists available XKW models for the 1000 Watt Series DC Power Supply.
Details the coverage and duration of the limited warranty for the power supply.
Provides contact information and steps for obtaining warranty service.
Lists exclusions and situations not covered by the limited warranty.
Warns about high energy, high voltage, and general operational hazards.
Provides cautions regarding operating environment and battery charging use.
Provides a general description of the XKW Series power supplies.
Describes the controls, LEDs, and meters on the power supply's front panel.
Describes the connectors and switches located on the rear panel of the power supply.
Presents detailed electrical specifications for the power supply models.
Explains remote control capabilities for start/stop, monitoring, and programming accuracy.
Provides mechanical details including dimensions, weight, and approvals.
Summarizes the steps for basic power supply setup and references detailed sections.
Provides instructions for initial inspection, periodic cleaning, and packaging.
Details the procedure for returning a unit for service or repair, including RMA.
Covers recommendations for unit placement, mounting in racks, and ventilation requirements.
Guides on AC input power connection, safety, and voltage selection for the unit.
Outlines procedures for performing functional tests on the power supply.
Provides guidance on connecting the load, wiring, grounding, and using sensing methods.
Guides on operating a single unit using front panel controls in local mode.
Discusses operating multiple power supplies in series, parallel, or split configurations.
Describes how to set and operate the Over Voltage Protection feature.
Explains how to control the power supply's output remotely using contact closures or relays.
Details how to remotely program output voltage and current limit using various methods.
Describes how to use and reset the Over Temperature Protection feature.
Details procedures and precautions for setting up calibration.
Explains the calibration process using multiturn trimpots and their locations.