EasyManua.ls Logo

Xerox WorkCentre PE114e - Scanner Ass’y

Xerox WorkCentre PE114e
114 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
5-4
Disassembly and Reassembly
Service Manual
5.4.1 Remove Scanner Ass’y
1. Before you remove the Scanner Ass'y, you should
remove:
-Rear Cover (see page 5-2)
-Side Cover(Left Cover, Right Cover)(see page 5-3)
2. Remove the 2 connectors from the main PBA and
release the ground wire from the Motor Drive Ass’y as
shown below.
3. Carefully lift the Scanner Ass’y from the base taking
care to thread the cables through the frame.
Scanner Assy
5.4 Scanner Ass’y
< Caution >
1. Before disassembling the Scanner Ass'y first lift
it carefully at the front edge. The support lever
will automatically raise into position.
2. Take care not to trap your fingers or hand in the
mechanism.

Related product manuals