EasyManuals Logo

Xinje DS5L Series User Manual

Xinje DS5L Series
174 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #154 background imageLoading...
Page #154 background image
146
P6-XX
Parameter
Function
Unit
Default
value
Range
Effective
Suitable mode
Reference
chapter
P6-05
Adaptive Mode Speed
Loop Gain (Large
Inertia)
0.1Hz
200
1~65535
1|2|3|4|5|6|7|10
6.2.4
P6-07
Adaptive mode inertia
ratio (Large inertia)
%
50
0~10000
1|2|3|4|5|6|7|10
6.2.4
P6-08
Gain of adaptive mode
speed observer (large
inertia)
Hz
40
10~1000
1|2|3|4|5|6|7|10
6.2.4
P6-12
Maximum Inertia Ratio
of Adaptive Mode
(Large Inertia)
-
50
1~10000
1|2|3|4|5|6|7|10
6.2.4
P7-XX
Parameter
Function
Unit
Default
value
Range
Effective
Suitable mode
Reference
chapter
P7-00
RS485 station no.
-
1
0~100
1|2|3|4|5|6|7|10
3.1.4
P7-01.0~1
RS485 baud rate
00
300
01
600
02
1200
03
2400
04
4800
05
9600
06
19200
07
38400
08
57600
09
115200
0A
192000
0B
256000
0C
288000
0D
384000
0E
512000
0F
576000
10
768000
11
1M
12
2M
13
3M
14
4M
15
5M
16
6M
Baud
rate
06
0~16
1|2|3|4|5|6|7|10
-
P7-01.2
RS485 stop bit
0
2 bits
2
1 bit
Stop
bit
2
0~2
1|2|3|4|5|6|7|10
-

Table of Contents

Other manuals for Xinje DS5L Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Xinje DS5L Series and is the answer not in the manual?

Xinje DS5L Series Specifications

General IconGeneral
BrandXinje
ModelDS5L Series
CategoryServo Drives
LanguageEnglish

Related product manuals