TH series Touchscreen User Manual Page 61 of 81 MANUL018R2V1
Next, we will introduce the each process:
1. Produce the data source: PSW300=PSW300+10 every 1 second:
Open the Touchwin software, click
Time
1. Collect data in loop
mode
2. Data source:
PSW300
3. Save object:
registers start from
PSW400
Data export to the registers
start from PSW400
Produce CSV format
file
Value
Select time: 1 second
History data map
Function filed
1. Data change every 1 second
PSW300=PSW300+10
2. PSW data change process:
1 secondPSW300=0
2 second: PSW300=10
3 secondPSW300=20
4 secondPSW300=30