EasyManua.ls Logo

Xinje VB5 - 2. Frequency Parameters (Group P1)

Xinje VB5
110 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
V5 series inverter
36
P0.15 Linear time of S
curve
10.0%~80.0%Acc/Dec time
P0.14P0.1590%
0.1% 60.0%
P0.16 Acc/Dec time unit 0: second
1: minute
0 0 ×
P0.17 Accerlate time 1 0.1~6000.0 0.1 10.0
P0.18 Decerlate time 1 0.1~6000.0 0.1 10.0
P0.19 High limit frequency Lowest frequency ~highest output
frequency P0.06
0.01Hz 50.00Hz ×
P0.20 Low limit frequency 0.00Hz~highest frequency 0.01Hz 0.00Hz ×
P0.21 Running mode of
lowest frequency
0: running at lowest frequency
1: stop
1 0 ×
P0.22 V/F curve setting 0: constant torque curve
1: torque-reducing curve 1 (1.2
powers)
2: torque-reducing curve 2 (1.7
powers)
3: torque-reducing curve 3 (2.0
powers)
4: multi-segment V/F curves
1 0 ×
P0.23 V/F frequency value
P1
0.00~P0.25 0.01Hz 0.00Hz ×
P0.24 V/F voltage value
V1
0~ P0.26 0.1% 0.0% ×
P0.25 V/F frequency value
P2
P0.23 ~ P0.27 0.01Hz 0.00Hz ×
P0.26 V/F voltage value
V2
P0.24 ~ P0.28 0.1% 0.0% ×
P0.27 V/F frequency value
P3
P0.25 ~ P0.07 basic running
frequency
0.01Hz 0.00Hz ×
P0.28 V/F voltage value
V3
P0.26 ~ 100.0% 0.1% 0.0% ×
2. Frequency parameter (Group P1)
Group P1: reference frequency parameter
Parameter Name Setting range
Minmum
unit
Default setting
Change
P1.00 Time constant of
analog filter
0.01~30.00s 0.01s 0.20s
P1.01 The gain of VI
channel
0.01~9.99 0.01 1.00
P1.02 min setting value of
VI
0.00~P1.04 0.01V 0.00V
P1.03 Frequency of the
min setting of VI
0.00~highest frequency 0.01Hz 0.00Hz
P1.04 Max setting of VI P1.04~10.00V 0.01V 10.00V
P1.05 Frequency of the
max setting of VI
0.00~highest frequency 0.01Hz 50.00Hz
P1.06 The gain of CI
channel
0.01~ 9.99 0.01 1.00
P1.07 Min setting of CI 0.00~ P1.09 0.01V 0.00V
P1.08 Frequency of the
min setting of CI
0.00~highest frequency 0.01Hz 0.00Hz

Table of Contents

Related product manuals