EasyManua.ls Logo

Xinje ZG3 Series - Page 50

Xinje ZG3 Series
93 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SD1171
Code of error pulse block
SD1180
Current segment(No. n segment)
PULSE_1
0
SD1182
Low 16 bits of accumulated pulse
number (the unit is pulse number)
SD1183
High 16 bits of accumulated pulse
number (the unit is pulse number)
SD1184
Low 16 bits of accumulated pulse
number(the unit is pulse equivalent)
SD1185
High 16 bits of accumulated pulse
number(the unit is pulse equivalent)
SD1186
Low 16 bits of current output
frequency(the unit is pulse number)
SD1187
High 16 bits of current output
frequency(the unit is pulse number)
SD1188
Low 16 bits of current output
frequency(the unit is pulse equivalent)
SD1189
High 16 bits of current output
frequency(the unit is pulse equivalent)
SD1190
Wrong Pulse message
1: Pulse data block error
2:Equivalent mode: pulse
amount/turn, amount/ turn of
movement is 0
3:Code of system parameters block
error
4:Pulse data block exceeds max limit
10:Zero return do not set near point
signal
11:Speed of zero return is 0
12:Crawling speed of zero return is
0
13 Direction of zero return speed and
zero auxiliary speed
SD1191
Code of error pulse block