EasyManua.ls Logo

Xinje ZG3 Series - PLC Specifications

Xinje ZG3 Series
93 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
ZG3 series
3
Language
Chinese, English, Spanish, Korean and so on
Font
Any font and size
Touch mode
4-wire resistance touch mode
Memory
Screen
128MB
Item
Spec
Program execution mode
Cyclic scan
Programming mode
Instruction, ladder chart, visual C
Operation speed
0.05µs
Latched
Flash ROM and Li-battery
User program capacity
1
128KB
I/O points
Input 16 points; output 14 points
Internal coil (X)
1048pointX0~X2027
Internal coil (Y)
1048pointY0~Y1037
Internal coil (MHM
11008 point
M0~M7999HM0~HM959
5
Special use
6
SM0~SM2047
Flow (S)
1152 point
S0~S1023HS0~HS127
Timer (T)
Points
704 points
T0~T575 HT0~HT95
Precise timer ET0~ET31
Spec
100ms timer: 0.1~3276.7 s
10ms timer: 0.01~327.67 s
1ms timer: 0.001~32.767 s
Counter
(C)
Points
704 points
C0~C575HC0~HC95
High speed counter HSC0~HSC31
Spec
16-bit counter: 0~32767
32-bit counter: -2147483648~2147483647
Data register (D)
11548 words
D0~D7999HD0~HD999
5
Special use
6
SD0~SD2047
Special use
6
HSD0~HSD499
FlashROM register (FD)
8144 words
FD0~FD6143
Special use
6
SFD0~SFD1999
High speed functions
High speed count, pulse output, external interruption
Scheduled scan time
0~99ms
Password protection
6-bit ASCII
Self diagnosis
Power-on self test, monitoring timer, grammar check
1: The max capacity in encrypting download mode
2 : I/O numbers means the input and output terminal numbers.
3X means input relaythe X points over input terminals can be mediate relay.
4Y means output relaythe Y points over output terminal can be mediate relay.
5:【】means power failure area ,cannot change.
PLC spec