SFD900
Pulse parameters setting
Bit 0logic of pulse output
0positive logic
1negative logic, default value is
0
Bit 1logic of pulse direction
0positive logic
1negative logicdefault value
is 0
Bit 8unit of pulse
0pulse number
1pulse equivalentdefault value
is 0
Common
parameters
pulse
_1
SFD901
Reserved
SFD902
Pulse number/1turn of low 16
bits
SFD903
Pulse number/1turn of high 16
bits
SFD904
Amount of movement/1turn of
low 16 bits
SFD905
Amount of movement/1turn of
high 16 bits
SFD906
Pulse direction terminal
Set number of terminal Y0xFF
means no terminal
SFD907
Direction delay time
Default value is 20unitms
SFD908
Positive compensation of gear
clearance
SFD909
Negative compensation of gear
clearance
SFD910
Low 16 bits of Electrical origin
position
SFD911
High 16 bits of Electrical origin
position
SFD912
Mechanical back to origin
parameter setting
Bit0Switch state setting of near
point, 0 Normally ON
1Normally OFF
SFD913
Terminal setting of near point
signal
Bit0~bit7Assign the number of
terminal X, 0Xff for not terminal
SFD914
Z phase terminal setting
Bit0~bit7Assign the number of
terminal X, 0Xff for not terminal