P12
StoppingModes
0: Inertial stop;
1: Deceleration stop;
2: Brake stop;
3: Emergency brake.
1
P13 Braking time 0---2.5 0.5 S
P14 BrakedVoltage 0---140.0 20 V
P15
RS485format
ASCII
0:7E1; 1:701; 2:8N2; 3:8E1;
4801.
2
P16 RS485 Baud rate
0 4800; 19600;
219200; 338400
1
P17 Machine number
1-255 1
P18 Operating arrival 0---100.0 50 Hz
P19 Persist
Over temperature
11
P20
Over temperature
protection selection
1---80 80
P21 Reduction ratio 1---100 1
P22
Carrier setting
1---10 10
P23
Frequency adjusting step
size
1---100 5 0.1Hz
P24
Overload protection buffer
time
0.1---60.0 3 S
P25
Motor series selection
0twopoles;
1quadrupole;
2sextupole.
0
P26
Working frequency
0---400.0 50 Hz