P08 is the hidden password, it always shows only 00000, not the actual
value.
When input the value of P09=the hidden value of P08, the P08 shows
hidden value, and the P08 and other parameters can be changed. The
P09 will be nullified when unplug the power cable to restart.
When P127=65535, the function of countdown do not start.
2. Parameter setting password and Down time stop:
P115
PID-I Coefficient
P116
PID-D Coefficient
P127
Remaining hours
0---65535 65535
H
17
When P127=65535, the function of countdown do not start.
When P12765535, the function of countdown will start, the P127
will minus 1 when the Inverter runs for one hour. The frequency
converter will be stopped when the countdown of P127 to 0 hour.
AT1:Parameters P15, P16, P17, P61, P92, P93, P94, P99,
P100, P105, P106, P107, P114, P115, P116 are nullified.
*93and*94arededicatedtothetimecountermodel
AT2:Parameters P15, P16, P17, P61, P99, P100, P105,
P106, P107, P114, P115, P116are nullified.
AT3:Parameters P92, P93, P94 are nullified.
3. Some parameters only support some models: