Hair Entanglement When the hair tangles or knots in the drain cover, trapping the swimmer underwater. This
hazard is present when the flow rating of the cover is too small for the pump or pumps.
Limb Entrapment When a limb is sucked or inserted into an opening resulting in a mechanical bind or swelling.
This hazard is present when a drain cover is missing, broken, loose, cracked or not properly secured.
Body En
trapment When a portion of the body is held against the drain cover trapping the swimmer underwater.
This hazard is present when the drain cover is missing, broken or the cover flow rating is not high enough for the
pump or pumps.
Evisceration/Disembowelment When a person sits on an open pool (particularly a child wading pool) or spa outlet
and suction is applied directly to the intestines, causing severe intestinal damage. This hazard is present when the
drain cover is missing, loose, cracked, or not properly secured. Mechanical Entrapment When jewelry, swimsuit,
hair decorations, finger, toe or knuckle is caught in an opening of an outlet or drain cover. This hazard is present when
the drain cover is missing, broken, loose, cracked, or not properly secured.
GENERAL SAFETY RULES
1. The products mentioned in this manual are specially designed for the pre-filtering and re-circulation of water in
swimming pools and spas.
2. They are designed to work with clean water at a temperature not exceeding 104
40!!
3. The installation should be carried out in accordance to the safety instructions of swimming pools, especially
Standard HD 384.7.702 , and the specific instructions for each facility.
4. The compulsory rules on accident prevention should be carefully followed.
5. Any modification of the pump requires the prior consent of the manufacturer. Original replacement parts and
accessories authorized by the manufacturer ensure a high level of safety. The manufacturer of the pump assumes no
liability for the damage and injuries caused by un-authorized replacement parts and accessories.
6. During operation, some parts of the pump are subject to dangerous electric voltage. Work may only be performed
on eac
h pump
or on the equipment connected to it after disconnecting them from the main power and after
disconnecting the starting device.
7. The user should make sure that assembly and maintenance tasks are carried out by qualified authorized persons
and that these persons have first carefully read the instructions for service and installation.
8. The operating safety of the pump is only guaranteed if the installation and service instructions are correctly
followed.
9. The limit values stated in the technical table should not be exceeded under any condition.
3
10. n the event of defective operation or fault, contact the technical support department of the manufacturer or its
nearest authorized agents.
11. f the supply cord is damaged, it must
be replaced by the manufacturer or its service agent or a similarly qualified
person to avoid a hazard.
12. The pump must not be used when people are in the water.
13. The pump must be supplied through a residual current device (RCD) having a rated residual operating current not
exceeding 30mA.
14. Children should be under close supervision to prevent them from playing with the pump.
15. This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental
capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning
use of the appliance by a person responsible for their safety.
16. The pump must be protected from running dry.