600 YRM 496 Valve Adjustment
Valve Adjustment
1. Rotate crankshaft until No. 1 piston is at TDC on
compressionstroke(intakeandexhaustvalves
closed).
2. Adjust clearance of intake valves for No. 1 and No. 2
cylinders and exhaust valves for the No. 1 and No. 3
cylinders. See Figure 52. Correct clearance for all
valves when engine is hot is 0.3 mm (0.012 in.).
To adjust clearance, loosen lock nut and turn ad-
justment screw. Tighten lock nut to 16 to 21 Nm
(12to15lbfft).
NOTE: During adjustment of valves, check position of
balls in ends of rocker arms. Flat surface of ball must
be in contact with stem of valve.
3. Rotate crankshaft clockwise one complete turn.
Adjust remaining valves.
4. If valves are adjusted when engine is cold, check
adjustments again after engine is warm.
A. INTAKE VALVES B. EXHAUST VALVES
1. CAMSHAFT
2. ROCKER ARM
3. BALL
4. VALVE STEM
Figure 52. Valve Adjustment