EasyManua.ls Logo

Yale GC080

Yale GC080
64 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Maintenance
CALIBRATION
PROCEDURES
GC/GLC030VX, GC/GLC035VX, GC/GLC040SVX [C809];
GLP/GDP16VX, GLP/GDP18VX, GLP/GDP20SVX (GP/GLP/
GDP030VX, GP/GLP/GDP035VX, GP/GLP/GDP040SVX) [C810];
GLC20-35VX (GC/GLC040-070VX, GC/GLC055SVX) [A910, B910];
GLP/GDP20-35VX (GP/GLP/GDP040-070VX) [B875, C875];
GLC40, 45, 55VX; GLC55SVX (GC/GLC080, 100, 120VX; GC/
GLC080, 100VXBCS; GC/GLC120SVX; GC/GLC120VXPRS)
[E818, F818];
GLP/GDP40VX5/VX6; GLP/GDP45SVX5, GLP/ GDP45VX6; GLP/
GDP50-55VX (GP/GLP/GDP080, 090, 100, 110, 120VX)
[F813, G813, H813, J813];
GLP/GDP60VX, GLP/GDP70VX; (GP/GLP/GDP135VX, GP/GLP/
GDP155VX) [C878, D878, E878];
GLC/GDC60VX, GLC/GDC70VX; (GC/GLC/GDC135VX, GC/GLC/
GDC155VX) [C879, D879, E879, F879];
GLP/GDP80VX, GLP/GDP80VX9, GLP/GDP90VX (GLP/GDP170VX,
GLP/GDP175VX36, GLP/GDP190VX) [A909, B909];
GLC030-035VX, GLC040SVX [D809];
GLP/GDP16-18VX, GLP/GDP20SVX (GLP/GDP030-035VX, GLP/
GDP040SVX) [D810];
GLC20-35VX (GC/GLC040-070VX, GC/GLC055SVX) [C910];
GLP/GDP20VX, GLP/GDP25VX, GLP/GDP30VX, GLP/GDP35VX
(GP/GLP/GDP040VX, GP/GLP/GDP050VX, GP/GLP/GDP060VX,
GP/GLP/GDP070VX) [D875]
This manual contains information that is confidential and/or proprietary to Yale Ma-
terials Handling Corporation, its subsidiaries and/or vendors. Copying or distribu-
tion of any sections of this manual marked "Confidential/Proprietary" is prohibited.
PART NO. 524223780 8000 YRM 1134

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Yale GC080 and is the answer not in the manual?

Yale GC080 Specifications

General IconGeneral
BrandYale
ModelGC080
CategoryTest Equipment
LanguageEnglish

Summary

Safety Precautions for Maintenance and Repair

Calibration Procedures Overview

Core Calibration Procedures

Service Password Entry

Procedure to access service menus by entering the correct password.

Hydraulic Valve Warm Up and Air Bleed

Prepares hydraulic system by warming fluid and removing air.

Save and Exit Calibration

Finalizes calibration by saving changes or discarding them.

Key Calibration Procedures

Lift Valve Output Threshold Calibration

Sets the 'cracking' current for the lift valve for proper operation.

Load Weight Zero Point Calibration

Establishes the baseline for accurate weight readings.

Transmission Valve Calibration

Adjusts clutch pack pressure for optimal transmission control.

Travel Speed Calibration

Ensures accurate speed input for transmission control functions.

Related product manuals