Do you have a question about the Yale GLP120VX and is the answer not in the manual?
| Model | GLP120VX |
|---|---|
| Load Capacity | 12000 lbs |
| Rated Load | 12000 lbs |
| Tire Type | Pneumatic |
| Fuel Type | LPG |
| Power Type | Internal Combustion |
| Battery Voltage | 12V |
| Weight | Approx. 17, 400 lbs (depending on configuration) |
Procedure to enter service password for accessing system menus.
Warms hydraulic fluid and bleeds air prior to calibration.
Saves calibration results and exits the calibration menu.
Calibrates the point where hydraulic flow begins for the lift valve.
Calibrates the point where hydraulic flow begins for the lower valve.
Calibrates the point where hydraulic flow begins for the tilt back valve.
Calibrates the point where hydraulic flow begins for the tilt forward valve.
Calibrates the point where hydraulic flow begins for Aux 1 Dir A.
Calibrates the point where hydraulic flow begins for Aux 1 Dir B.
Calibrates the point where hydraulic flow begins for Aux 2 Dir A.
Calibrates the point where hydraulic flow begins for Aux 2 Dir B.
Calibrates the point where hydraulic flow begins for Aux 3 Dir A.
Calibrates the point where hydraulic flow begins for Aux 3 Dir B.
Sets the zero point for load weight display calibration.
Calibrates the system for accurate loaded weight display.
Compensates for clutch pack control valve pressure.
Calibration for electronic extended function transmission.
Calibration for electronic and electronic extended transmission functions.
Adjusts throttle assembly for proper clutch pack braking and inching.
Installs a pressure gauge for pressure method calibration.
Ensures accurate travel speed information for advanced functions.
Loading...