Command Class Configuration, Version 4*
* This command class requires security.
Table 8 - Configurable Parameters
Param.
Num.
Name
Length
Configuration Properties
Info
Length
of Info
String
Min
Max
Default
(max
length
allowed
is 90)
1
Volume
1 byte
0x01
(High
Volume)
0x03
(Silent)
0x02 (Low
Volume)
[0x8002,
0x8109,
0x8103]
Set Volume Level to high (1),
low (2), or silent (3).
[0x8002, 0x8109, 0x8103
& 0x8104]
53
0x01 (High
Volume)
[0x810A,
0x8004 &
0x8104]
Set Volume Level to high (1)
or silent (3). [0x810A &
0x8004]
44
2
Auto Relock
1 byte
0x00
(Disable)
0xFF
(Enable)
0x00
(Disable)
Set Auto Relock feature to
enable or disable.
45
3
Relock time
1 byte
0x0A (10
seconds)
0xB4 (180
seconds)
0x1E (30
seconds)
Adjust the time your lock will
auto relock.
43