704-010
4. Pull slowly on the recoil starter until it is
engaged, then pull it briskly.
5. After the engine starts, warm up the engine
until the engine does not stop when the choke
lever is returned to the operating position.
6. Turn the choke lever back to the operating
position.
1 Operating position
14
701-025
q
NOTE:
9 “~” means below.
9 Application wattage indicates when each appa-
ratus is used by itself.
cC
Be sure the total load is within generator rated
output otherwise generator damage will occur.
NOTE:
Some precision equipment is voltage sensitive and
may require a more uniform voltage supply than
portable generators provide. Examples include
some medical equipment, personal computers,
and some inverters that sense peak and RMS volt-
age values. Consult the precision-equipment ven-
dor before relying on any portable generator to
provide power to such equipment.
G-43101
APPLICATION RANGE
AC
Power factor 1 0.8 ~ 0.95
0.4 ~ 0.75
(Efficiency 0.85)
EF2600A ~ 2,300W ~ 1,840W ~ 780W
EF4600A ~ 4,000W ~ 3,200W ~ 1.360W
EF6600A ~ 5,700W ~ 4,560W ~ 1,940W