– 35 –
ç Economy control switch
NOTICE
Reduce the load to the specified generator rated
output if the AC switch (N.F.B.) turns off. If it turns
off again, consult a Yamaha dealer.
TIP
9 The 4-blade plug receptacle can supply both
120 V and 240 V power sources.
9 The economy control switch must be turned to “3
(OFF) to increase engine speed to rated r/min
when:
- using a load of 0.8 A or less.
- supplying AC 120 V only from W with X.
5. Turn the individual AC switch (N.F.B.) to “I” (ON).
4 “I” (ON)
å Individual AC switch (N.F.B.) for AC receptacle
4
A
4
4
B
240V
120V
120V
GR
W
X
G
Y
AC 120 V and 240 V can be used.
3
C
3
A
3
3
B
4. Turn the AC switch (N.F.B.) and economy control
switch to “I” (ON) and turn on any electric devices.
3 “I” (ON)
å AC 120 V can be used.
Individual AC switch (N.F.B.) for G. F. C. I. receptacle
7P5-F8199-14.indd 35 2021/06/23 11:22:17