8-10
BATTERY WIRING
RECOMMENDED EXTENSION LENGTH OF BATTERY CABLES
To be continued.
Atmosphere temperature is below 0°C (32°F)
Applicable models
Battery Maximum total extension length
Unit Rating
AWG4
20 mm
2
AWG2
30 mm
2
AWG1/0
50 mm
2
AWG2/0
60mm
2
Carbureted 150 – 225
(V6-2.6L)
Carbureted 250 (V6-3.1L)
4-stroke 115, 150 &
VMAX (SHO) (V-4.2L)
Cannot be extended
HPDI (V6-2.6L)
CCA/SAE 696 amps
2.8 m
(9 ft)
4.8 m
(16 ft)
7.4 m
(24 ft)
MCA/ABYC 856 amps
RC/SAE 167 min
CCA/EN 711 amps
20HR/IEC 83 Ah
JIS 95D31
HPDI (V6-3.3L)
CCA/SAE 696 amps
3.9 m
(13 ft)
6.7 m
(22 ft)
10.4 m
(34 ft)
MCA/ABYC 856 amps
RC/SAE 167 min
CCA/EN 711 amps
20HR/IEC 83 Ah
JIS 95D31
4-stroke 150 (VMAX), 165, 175,
200 (L4-2.8L)
CCA/SAE 800 amps
1.8 m
(5.9 ft)
2.7 m
(8.9 ft)
4.5 m
(14.8 ft)
5.4 n
(17.7 ft)
MCA/ABYC 960 amps
RC/SAE 230 min
CCA/EN 750 amps
20HR/IEC 120 Ah
JIS 130E41
4-stroke 200, 225, 250
(V6-3.3L)
CCA/SAE 696 amps
3.5 m
(11 ft)
6 m
(20 ft)
9.2 m
(30 ft)
MCA/ABYC 856 amps
RC/SAE 167 min
CCA/EN 711 amps
20HR/IEC 83 Ah
JIS 95D31

Table of Contents