44
14. Standard installation manual
*Install the product according to the following: (Confirm separately for optional items or special
specifications)
Model Serial number Date
Installation
mgr.(company name)
Installation mgr.
Judg
ment
№ Item Implementation method
TOC No. Reference page of the
operating instruction manual
Judg
ment
Specifications
1
Included
items
Check for number of staffs against
the included item field
10.Specifications field P.40
・ Visual check of environmental
conditions
Caution:
Take care for environment
2 Installation
・Securing a space
2. Before operating the
unit
・ On the installation site
P. 4
Operation-related matters
1
Source
voltage
・ Measure the user side voltage
(outlet) with a tester
・ Measure voltage during operation
(shall meet the specifications)
Caution:
Always use a plug that meets the
specification for attaching to the
ELB.
2. Before operating the unit
・ Be sure to connect the
ground wire.
・ Power supply is ….
10.Specifications
・Specification - power
supply
P. 4
P. 7
P.40
2
Operation
start
・Starts operation
Performs fixed temperature
operation, auto stop operation,
auto start operation, or program
operation.
2. Before operating the unit
・Installation
procedures…
4. Operating procedures
P. 4 ~
8
P.13~
32
Description
1
Operational
descriptions
Explain operations of each com-
ponent according to the operational
instructions
4. Operating procedures
・Operating procedures
1. Safety precautions
〜13. List of dangerous
materials
P.13~
32
P. 1
〜43
8. Troubleshooting
〜9. After sales service
and warranty
2 Error codes
Explain the customer about error
codes and procedures for release
according to the operational
instructions
P.37
39
3
Maintenance
and
inspection
Explain operations of each com-
ponent according to the operational
instructions
6. Maintenance
procedures
・Daily inspection/
maintenance
P.35
9. After sales service and warranty
4
Completion
of installation
Entries
・ Fill in the installation date and the
installation mgr. on the nameplate
of the main unit
・ Fill in necessary information to
the warranty card and hand it
over to the customer
・ Explanation of the route for
after-sales service
P.39