BRAKING UNIT CDBR-
BRAKING RESISTOR UNIT LKEB-
Braking unit,
Braking resistor unit
YASKAWA AC Drive Option
Installation Manual
To properly use the product, read this manual thoroughly and retain
for easy reference, inspection, and maintenance. Ensure the end user
receives this manual.
MANUAL NO. TOBP C720600 00F
製品を安全にお使い頂くために,本書を必ずお読みください。
また,本書をお手元に保管していただくとともに,最終的に本製品をご使用になる
ユーザー様のお手元に確実に届けられるよう,お取り計らい願います。

Questions and Answers

  • C
    Christopher TorresJul 29, 2025
    Why does my YASKAWA DC Drives inverter trip at overvoltage?
    • A
      Ashley MartinJul 29, 2025
      If your YASKAWA DC Drives inverter trips at overvoltage (OV), this could be due to insufficient braking resistor unit capacity. In this case, examine the braking conditions again. It could also be caused by improper wiring, so check and repair the wiring. Another cause could be a fault in the braking unit, so replace the unit.
  • C
    Charles HartAug 4, 2025
    What to do if YASKAWA DC Drives braking unit trips by heat sink overheat?
    • S
      Sarah AriasAug 4, 2025
      If the braking resistor unit overload relay (or thermal protector) of your YASKAWA DC Drives trips due to heat sink overheat, this could be due to several reasons. It may be caused by an excessive start/stop switching frequency, so examine the operating conditions. The issue could also stem from excessive load inertia. Improper combination of braking unit and braking resistor unit can cause this problem, so reset it. High ambient temperature could be the reason, so reduce it. Finally, the braking unit itself might be faulty, so replace the unit.
  • B
    Benjamin MejiaAug 10, 2025
    Why does YASKAWA CDBR braking resistor unit overload relay trip when not decelerating?
    • P
      ploweAug 10, 2025
      If the braking resistor unit overload relay (or thermal over-load protector) of your YASKAWA DC Drives trips when not decelerating, and you don't have a braking unit, the inverter's built-in main circuit discharging transistor may be short-circuited; replace the inverter. If you do have a braking unit, the braking unit's main circuit discharging transistor may be short-circuited; replace the unit. Another cause could be an improper braking unit power supply voltage selection connector setting. If the power supply voltage is greater than the power supply voltage selection position, set it again.
  • K
    Kendra MahoneyAug 16, 2025
    What to do if the fault contact of YASKAWA DC Drives braking unit instantaneously turned ON?
    • J
      Jacqueline CampbellAug 16, 2025
      If the fault contact of a braking unit in your YASKAWA DC Drives instantaneously turned ON when the power was turned ON, it could be because neither a braking resistor nor a braking resistor unit is connected to the braking unit. Connect a braking resistor or braking resistor unit to the braking unit to resolve this issue.
  • J
    James CoxAug 21, 2025
    Why YASKAWA CDBR DC Drives braking resistor unit overload relay sometimes trips?
    • T
      toniwatkinsAug 21, 2025
      If the braking resistor unit overload relay (or thermal protector) of your YASKAWA DC Drives sometimes trips, this may be due to insufficient braking resistor unit capacity. Examine the braking conditions again to address this issue.

Summary

2 INSTALLATION

2.2 INSTALLATION

Instructions for mounting and spacing the units for optimal performance.

3 WIRING

3.3 CIRCUITS AND WIRING SPECIFICATIONS

Technical details on circuit diagrams and required wire specifications.

3.4 WIRING PRECAUTIONS

Critical safety and performance guidelines for wiring the units.

4. OPERATION

4.2 POWER SUPPLY VOLTAGE SELECTION CONNECTOR SETTING

How to set the voltage selection connector for correct operation.

4.4 PARALLEL CONNECTION OF BRAKING UNIT

Guidelines for connecting multiple braking units in parallel.

5 TROUBLESHOOTING

6 SPECIFICATIONS

6.4 BRAKING UNIT SPECIFICATIONS

Detailed technical specifications for various braking unit models.