7.5.5 External Terminal Functions: H
7-80
D
The analog input signal level, gain, and bias are set with the following constants.
Terminal 16 signal level selector
H3-04 (0 to +10 V or 0 to
±
10 V)
Terminal 16 input gain H3-06
Terminal 16 input bias H3-07
Terminal 14 signal level selector H3-08 (0 to +10 V, 0 to ±10 V, or 4 to 20 mA)
Terminal 14 input gain H3-10
Terminal 14 input bias H3-11
D
When a voltage input is being input to terminal 14, be sure to disconnect jumper wire J1 on the control
PC board.
D The input resistance will be destroyed if a voltage input is used without disconnecting the jumper wire.
(Refer to Torque Reference Settings: H3-04, H3-05, H3-08, H3-09 in 7.3.3.)
D
Set the time constant in constant H3-12 when adding a primary delay filter to an analog input. This
filter time constant applies to all three of the analog inputs.
D
Settings 2 and D cannot be set at the same time. OPE07 will be detected.