EasyManua.ls Logo

YASKAWA CIMR-G5A 23P7 - Programming Mode Constant Groups

YASKAWA CIMR-G5A 23P7
355 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Setting User Constants
4.2.6 Programming Mode
4-26
Table
4.5 Programming Mode Constant Groups
Control Meth-
od
Group Function Display Comments
V/f
V/f w/PG
Open-loop Vector
Flux Vector
b1 Operating modes Sequence
Settings such as the reference input
method
f f f f
b2 DC braking DC Braking
DC braking function settings
f f f f
b3 Speed searching Speed Search
Speed search function settings
f f f f
b4 Timer functions Delay Timers
Timer function settings
f f f f
b Application
b5 PID control PID Control
PID control settings
f f f f
pp
b6 Dwell functions Reference Dwell
Accel/decel time dwell function settings
f f f f
b7 Droop control Droop Control
Droop control (speed drop) settings
× × ×
f
b8 Energy-saving control Energy Saving
Terminal input energy-saving control
settings
f f
× ×
b9 Zero servo Zero Servo
Stop in the position loop
× × ×
f
C1
Acceleration/deceleration
times
Accel/Decel
Acceleration/deceleration time settings
f f f f
C2
S-curve acceleration/de-
celeration
S-Curve Acc/Dec
S-curve characteristics for accel/decel
times
f f f f
C3 Slip compensation Motor-Slip Comp
Slip compensation function settings
f f f f
C
T
uning
C4 Torque compensation Torque Comp
Torque compensation function settings
f f f
×
C Tuning
C5 Speed control ASR Tuning
Speed control loop user constant set-
tings
×
f
×
f
C6 Carrier frequencies Carrier Freq
Carrier frequency settings
f f f f
C7
Hunting prevention func-
tions
Hunting Prev
Hunting prevention function for V/f
control
f f
× ×
C8 Factory tuning constants Factory Tuning
Adjustment for open-loop vector control
× ×
f
×
d1 Frequency references Preset Reference
Operator frequency reference settings
f f f f
d2
Frequency upper/lower
limits
Reference Limits
Frequency upper and lower limit set-
tings
f f f f
d Reference
d3 Jump frequencies Jump Frequencies
Prohibited frequency settings
f f f f
d4
Reference frequency hold
function
Sequence
Hold for analog frequency reference
f f f f
d5 Torque control Torque Control
User constant settings for torque control
× × ×
f
E1 V/f characteristics V/f Pattern
Sets the motor V/f characteristics.
f f f f
E2 Motor constants Motor Setup
Sets the motor constants.
f f f f
E Motor
E3 Motor 2 control method Motor 2 Ctl Meth
Sets the control methods for motor 2.
f f f f
E4 V/f Characteristics 2 V/F pattern 2
Sets the V/f characteristics for motor 2.
f f f f
E5 Motor 2 constants Motor 2 Setup
Sets the motor constants for motor 2.
f f f f