Do you have a question about the YASKAWA CIMR-G5A Series and is the answer not in the manual?
Series | CIMR-G5A |
---|---|
Category | Inverter |
Overload Capacity | 150% for 60 seconds |
Cooling Method | Fan Cooled |
Control Method | V/f Control |
Protection Functions | Overcurrent, Overvoltage, Undervoltage, Overheating, Short Circuit, Ground Fault |
Communication Options | Modbus RTU, DeviceNet, Ethernet/IP |
Operating Temperature | -10°C to +50°C (14°F to 122°F) |
Humidity | 95% RH or less (non-condensing) |
Enclosure Rating | IP20 |
Input Voltage | 200-240V, 380-480V, 500-600V |
Output Voltage | 3-phase, 0 to Input Voltage |
Precautions and instructions for correctly wiring the inverter's main and control circuits.
Detailed wiring diagram showing connections for main circuits and control circuits.
Details on applicable wire sizes, connectors, and terminal functions for main circuits.
Specifications for wire sizes, connectors, and terminal functions for control circuits.
Explanation of access levels (Quick-start, Basic, Advanced) that govern user constant visibility and modification.
Details on operating the inverter, including monitoring parameters and fault trace.
Procedures for selecting language, access level, control method, and initializing user constants.
Instructions for setting user constants, organized by groups (Application, Tuning, Reference, Motor, Options, Terminal, Protection, Operator).
Procedure for automatically tuning motor constants for vector control modes.
Detailed steps for Power ON, checking display status, initializing constants, and setting input voltage.
Procedure for autotuning motor constants, including precautions and troubleshooting.
Advanced functions for open-loop vector control, including torque limits and speed feedback adjustment.
Advanced functions for flux vector control, including droop control, zero-servo, torque control, and speed/torque switching.
Lists all user constants available in programming mode, categorized by function group.
Constants related to inverter and motor protection functions, including overload, stall prevention, and fault detection.
Description of fault displays, probable causes, and corrective actions for inverter faults.
Details on minor faults, their probable causes, and recommended countermeasures.
List of operation error codes, meanings, incorrect settings, and corrective actions.
Troubleshooting guide for scenarios where the motor fails to operate correctly.
Detailed specifications for 200 V and 400 V class VS-616G5 inverters.
Comprehensive list of all user constants, their settings, and applicable control methods.