8.2 Programming Mode Constants
8-9
Constant
Number
Page
Control Methods
Change
during
Opera-
tion
Factory
Setting
Setting
Range
Description
Name
Constant
Number
Page
Flux
Vector
Open
Loop
Vector
V/f
with
PG
V/f
Change
during
Opera-
tion
Factory
Setting
Setting
Range
Description
Display
b5-13
PID feedback com-
mand loss detection
level
Sets the PID feedback loss detec-
tion level in % units, with the
maximum output frequency at
100%.
0 to 100 0
×
A A A A
7-50
Fb los DET Lvl
b5-14
PID feedback com-
mand loss detection
time
Sets the PID feedback loss detec-
tion level in s units.
0.0 to
25.5
1.0
×
A A A A
7-50
Fb los Det Time
.
J
Dwell Functions: b6
Con-
Name
Change
Control Methods
stant
Num-
ber
Display
Description
Setting
Range
Factory
Setting
during
Opera-
tion
V/f
V/f
with
PG
Open
Loop
Vector
Flux
Vector
Page
Dwell frequency
at start
0.0 to
b6-01
Dwell Ref @
Start
Out
ut fre
uenc
Run command
ON
OFF
.
400.0
0.0
×
A A A A
7-52
Dwell time at start
b6-02
Dwell Time @
Start
0.0 to
10.0
0.0
×
A A A A
7-52
b6-03
Dwell frequency
at stop
b6-01
b6-03
me
0.0 to
0.0
×
A A A A
7-52
Dwell Ref @ Stop
The dwell function is used to hold the
b6-02 b6-04
400.0
.
Dwell time at stop
output frequency temporarily when
b6-04
Dwell Time @
Stop
driving a motor with a heavy load.
0.0 to
10.0
0.0
×
A A A A
7-52
J
Droop Control: b7
Name
Change
Control Methods
Constant
Number
Display
Description
Setting
Range
Factory
Setting
during
Opera-
tion
V/f
V/f
with
PG
Open
Loop
Vector
Flux
Vector
Page
Droop control gain
Sets the slip as a percentage of
maximum frequency when the
maximum output frequency is
-
0.0 to
b7-01
Droop Gain
spec
e
an
t
e rate
torque oc-
curs.
:Droop-control is not performed
when the setting is 0.0.
.
100.0
0.0
f
× × ×
A
7-18
b7-02
Droop control delay
time
Droop control responsiveness
constant
0.03 to
0.05
f
× × ×
A
7-18
Droop Delay Time
:When hunting or oscillation oc-
curs, increase the value.
2.00
.
8