4.2 Modes
4-13
Func-
tion
Valid Access Levels
Min.
Unit
Output Signal Levels for
Multi-function Analog Out-
puts
Function
Name
Con-
stant
No.
Func-
tion
Flux
Vec-
tor
Open
-loop
Vec-
tor
V/f w/
PG
V/f
Min.
Unit
Output Signal Levels for
Multi-function Analog Out-
puts
Function
Digital Operator
Display
Con-
stant
No.
U1 12
Operation status
Inverter operating status.
U1-12 = 00000000
1: Running
1: Zero-speed level
1:
Reverse
Can
t
be
output
Q
Q
Q
Q
U1-12
Int Ctl Sts 1
1: Reverse
1: Reset input ON
1: F.ref/F.out agree
1: Inverter ready
1: Minor fault detected
1: Major fault detected
Can’t be output. −−
Q Q Q Q
U1-13
Cumulative opera-
tion time
Monitors the Inverter’s elapsed
operating time.
The initial value and running/
ti
lti
b
Can’t be out
p
ut. 1hr
Q Q Q Q
U1 13
Elapsed Time
g
power-on time selection can be
set with user constants o2-07
and o2-08.
Can
t
be
output
.
1
hr
Q
Q
Q
Q
U1 14
Software No.
Manufacturer
s
ID
number
Can
t
be
output
Q
Q
Q
Q
U1-14
FLASH ID
Manufacturers ID number Can’t be output. −−
Q Q Q Q
U1-15
Terminal 13 input
voltage level
Monitors the input voltage of
the frequency reference (volt-
age).
10 V: 100% (10 V)
(0
t
10
V
ibl )
0.1%
B B B B
U1 15
Term 13 Level
g)
An input of 10 V corresponds to
100%.
(0 to ±10 V possible)
0
.
1
%
B
B
B
B
U1-16
Terminal 14 input
current level
Monitors the input current of the
frequency reference (current).
A
it
f
20
A
d
20 mA: 100% (20 mA)
(0
t
+10
V
tt)
0.1%
B B B B
U1 16
Term 14 Level
An input of 20 mA corresponds
to 100%.
(0 to +10 V output)
0
.
1
%
B
B
B
B
Status
Moni-
t
U1-17
Terminal 16 input
voltage level
Monitors the input voltage of
the multi-function analog input.
A
it
f
10
V
d
t
10 V: 100% (10 V)
(0
t
10
V
ibl )
0.1%
B B B B
tor
U1 17
Term 16 Level
An input of 10 V corresponds to
100%.
(0 to ±10 V possible)
0
.
1
%
B
B
B
B
U1-18
Motor secondary
current (lq)
Monitors the calculated value of
the motors secondary current
(Iq).
10 V: Rated secondary current
(0
t
+10
V
tt)
0.1%
B B B B
U1 18
Mot SEC Current
(q)
The motor ’s rated secondary
current corresponds to 100%.
(0 to +10 V output)
0
.
1
%
B
B
B
B
U1-19
Motor exciting cur-
rent (ld)
Monitors the calculated value of
the motors excitation current
(Id).
10 V: Rated secondary current
(0
t
+10
V
tt)
0.1%
× ×
B B
U1 19
Mot EXC Current
()
The motor ’s rated secondary
current corresponds to 100%.
(0 to +10 V output)
0
.
1
%
×
×
B
B
U1-20
Output frequency
after soft-start
Monitors the output frequency
after a soft start.
The display shows the frequen-
ith t
th
ti
f
10 V: Max. frequency
(0
t
10
V
ibl )
0.01
Hz
A A A A
U1 20
SFS Output
py
q
cy without the correction from
compensation functions such as
slip compensation.
(0 to ±10 V possible)
Hz
A
A
A
A
U1 21
ASR input
Monitors the input to the speed
control loop.
10 V: Max. frequency
0
01
%
×
A
×
A
U1-21
ASR Input
control
loop.
The max. frequency corresponds
to 100%.
10
V
:
Max.
frequency
(0 to ±10 V possible)
0.01 %
×
A
×
A
U1 22
ASR output
Monitors the output from the
speed control loop.
10 V: Rated secondary current
0
01
%
×
A
×
A
U1-22
ASR Output
speed
control
loop.
The motor ’s rated secondary
current corresponds to 100%.
10
V
:
Rated
secondary
current
(0 to ±10 V possible)
0.01 %
×
A
×
A
U1 23
Speed deviation
Monitors the speed deviation
within the speed control loop.
10 V: Max. frequency
0
01
%
×
A
×
A
U1-23
Speed Deviation
within
the
speed
control
loop.
The max. frequency corresponds
to 100%.
10
V
:
Max.
frequency
(0 to ±10 V possible)
0.01 %
×
A
×
A
4