17
Other Functions
Display
Status Indicator LED RUN and ALARM provided as standard LED’s
Digital Operator
(JVOP-140)
Available to monitor frequency reference, output frequency,
output current. 3 character, 7 segment LED Display.
Terminals
Main circuit: screw terminals
Control circuit: plug-in screw terminal
Wiring Distance between
Inverter and Motor
328ft (100m) or less‡
Enclosure Open chassis
Cooling Method
Cooling fan is provided for 200V, 0.75kW (3-phase), 400V,
1.5kW (single-phase), others are self-cooling
Environmental
Conditions
Ambient Temperature
Open chassis: -10 to +50°C (14 to 122°F)
(not frozen)
Humidity 95% RH or less (non-condensing)
Storage Temperature† -4 to 140°F (-20 to +60°C)
Location Indoor (free from corrosive gases or dust)
Elevation 3280ft (1000m) or less
Vibration
Up to 9.8m / S
2
(1G) at less than 20Hz, up to 2m / S
2
(0.2G) at
less than 20 to 50Hz
Temperature during shipping (for short period)
‡ If the wiring distance between inverter and motor is long, reduce the inverter carrier frequency.
For details, refer to “Reducing motor noise or leakage current (n46)”on page 79.
Voltage Class 200V single- / 3-phase
Model
CIMR-J7AU!!!!
3-phase 20P1 20P2 20P4 20P7 21P5 22P2 23P7
Single-phase B0P1 B0P2 B0P4 B0P7 B1P5 - -