58
Selecting V/f pattern
Adjust motor torque by using “V/f pattern” and “full-range automatic torque boost”.
V/f pattern setting
Set V/f pattern by parameters n09 to n15 as described below. Set each pattern when
using a special motor (high-speed motor, etc.) or when requiring special torque
adjustment of machine.
Be sure to satisfy the following conditions for
the setting of n09 to n15.
n14 <
n12 < n11 < n09
If n14 = n12, the set value of n13 is disabled.
Adjusting torque according to application
Parameters
No.
Name Unit Setting range Initial Setting
n09 Max. output frequency 0.1Hz 50.0 to 400Hz 60.0Hz
n10 Max. voltage 1V
1 to 255V
(0.1 to 510V)
230V
(460V)
n11
Max. voltage output frequency
(base frequency)
0.1Hz 0.2 to 400Hz 60.0Hz
n12 Mid. output frequency 0.1Hz 0.1 to 399Hz 1.5Hz
n13 Mid. output frequency voltage 1V
0.1 to 255V
(0.1 to 510V)
12V
(24V)
n14 Min. output frequency 0.1Hz 0.1 to 10.0Hz 1.5Hz
n15 Min. output frequency voltage 1V
1 to 50V
(0.1 to 100V)
12V
(24V)