70
At OFF: n16 (accel time 1) are used.
n17 (decel time 1)
At ON: n18 (accel time 2) are used.
n19 (decel time 2)
Accel time
Set the time needed for output frequency to reach 100% from 0%.
Decel time
Set the time needed for output frequency to reach 0% from 100%.
(Maximum output frequency n09 = 100%)
The inverter has the ability to ride thru momentary power outages provided the control
logic power supplies are maintained.
When momentary power loss occurs, operation restarts automatically.
* Maintain the run command to continue operation after recovery from a momentary power loss.
When 2 is selected, operation restarts if power supply voltage reaches its normal level while control
power supply is held. No fault signal is output.
Automatic restart after momentary power
loss (n47)
Setting. Description
0 Continuous operation after momentary power loss not provided.
1*
Continuous operation after power recovery within momentary
power loss ride thru time is provided.
2*
Continuous operation after power recovery (Fault output not
provided)