EasyManua.ls Logo

yellow jacket 37882 - LCD Error Messages and Solutions

Default Icon
16 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
15
LCD Error Messages and Potential Solution
ERROR
NUMBER
MESSAGE DESCRIPTION TROUBLESHOOTING
ERROR 1 HIGH PRESSURE HIGH PRESSURE SWITCH IS TRIPPED
(NORMALY CLOSED SWITCH)
 OPEN TANK VALVE
 TEST HIGH PRESSURE SWITCH
 CHECK SV AND CHECK VALVE OP
 CHECK TANK PRESSURE
ERROR 2 TANK FULL TANK WEIGHT OVER 80% OF CAPACITY
 CHECK SCALE CALIBRATION
 REMOVE SOME REFRIGERANT
FROM STORAGE TANK
ERROR 3
RECOVERY TIME
OUT
RECOVERY PROCESS HAS EXCEEDED
1 HR FACTORY DEFAULT
 IF AC SYSTEM CONTAINS MORE
THAN 3 LBS OF REFRIGERANT
INCREASE DEFAULT TIME
 CHECK FOR LEAKS (HOSES, FIT-
TINGS AND AUTO AC SYSTEM
ERROR 4
CHARGING TIME
OUT
CHARGING PROCESS HAS EXEEDED
20 MIN FACTOR DEFAULT
 OPEN TANK VALVES
 OPEN SERVICE COUPLERS
 SWITCH TO LOW SIDE CHARGING
 CHECK TANK WEIGHT (10 LB MIN)
ERROR 5
NO TANK ON
SCALE
SCALE NOT READING TANK WEIGHT
 PLACE TANK ON SCALE
 CHECK SCALE CALIBRATION
ERROR 6 TANK EMPTY
REFRIGERANT BELOW 5 % OF
TANK CAPACITY
 REFILL TANK
 CHECK SCALE CALIBRATION
ERROR 7
NOT ENOUGH
REFRIGERANT
UNIT IS LOW ON REFRIGERANT
(10 LB MIN)
 REFILL TANK
ERROR 8
TANK REFILL
TIME OUT
TANK REFILL HAS EXCEEDED
DEFAULT TIME
 RUN TANK REFILL MODE AGAIN
 CHECK FOR LEAKS
 TEST LOW PRESSURE SWITCH
ERROR 9
VACUUM TIME
OUT. PLEASE
CHECK FOR
LEAK
 NOT USED
ERROR 10
SYSTEM
EQUALIZED
PRESSURE EQUALIZED DURING
CHARGING
 INCREASE VACUUM TIME
 RUN THE VEHICLE TO DRAW IN THE
REMAINING REFRIGERANT
CHARGE
ERROR 11
HOSE CLEARING
TIME OUT
CLEARING TIME OUT AFTER
CHARGING
 CLOSE SERVICE VALVES AND DIS-
CONNECT
ERROR 12
POSSIBLE OVER
CHARGE
POTENTIAL OVERCHARGE OF THE
VEHICLE
 REPEAT RECOVERY AND CHARGE
PROCESS
ERROR 13 VACUUM ERROR
LP SWITCH OPENED DURRING
VACUUM HOLD
 REPEAT VACUUM CYCLE
ERROR 14
LEAK CHECK
FAILD
FAILED TO HOLD VACUUM AFTER 5
ATTEMPTS
 REPEAT RECOVERY PROCESS
 CHECK FOR LEAKS
ERROR 15
SYSTEM
MALFUNCTION
EEP-ROM DATA READ/WRITE ERROR
 REPLACE MICROPROCESSOR
ERROR 16 IDENT ERROR IDENTIFIER ERROR
 CALL TECH-SUPPORT

Related product manuals