EasyManua.ls Logo

York Affinity PC9 - THERMOSTAT CHART - SINGLE STAGE AC

York Affinity PC9
8 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
036-21671-001 Rev. A (0106)
Unitary Products Group 5
For additional connection diagrams for all UPG equipment refer to “Line Voltage System Wiring” document available online at
www.upgnet.com in the Product Catalog Section.
THERMOSTAT CHART - SINGLE STAGE AC
AC20
Single Stage A/C w/Modulating Furnace, 2 Stage Cooling Ready - P(C/M)8/9
THERMOSTAT THERMOSTAT THERMOSTAT
*BN11C01124
MODULATING
FURNACE CONTROL
SINGLE STAGE
AIR CONDITIONING
*BN11C00124 *BP11C50124 *PP11C70224
*DP11C40124
*DN11C00124
C
24-Volt Common
C
24-Volt Common
Optional w/Batteries
C
24-Volt Common
C
24-Volt Common
Y
First Stage Cool
Y
First Stage Cool
Y
First Stage Cool
Y/Y2
Single/Second Stage Cool
Y
Single Stage Cool
Y1
First Stage Cool
RC
24-Volt Hot (Cool XFMR)
RC
24-Volt Hot (Cool XFMR)
RC
24-Volt Hot (Cool XFMR)
HUM
Dehumidification - Open on Humidity
Rise
HUMIDISTAT
1
R
24-Volt Hot (Heat XFMR)
RH
24-Volt Hot (Heat XFMR)
RH
24-Volt Hot (Heat XFMR)
R
24-Volt Hot
24V HUMIDIFIER
G
Fan
G
Fan
G
Fan
G
Fan
W
First Stage Heat
W
First Stage Heat
W
First Stage Heat
W
Heat (Modulating)
HM1
Humidistat
Thermostat Installer Setup Number 1 -
System Type - must be set to 0
Selection of GAS/ELEC switch
on thermostat not necessary
Thermostat Installer Setup Number 15 -
Compressor Protection - must be set to 5
NOTE: JUMPER ON FURNACE
CONTROL TO BE IN 'YES' POSITION
IF HUMIDISTAT IS INSTALLED
1
OPTIONAL DEHUMIDIFICATION -
HUMIDISTAT CONTACTS OPEN ON
HUMIDITY RISE