TECHNICAL GUIDE
UP TO 98%
MODULATING (ECM MOTOR)
GAS-FIRED RESIDENTIAL
MULTI-POSITION GAS FURNACES
MODELS: YP9C*C
NATURAL GAS
60 - 120 MBH INPUT
Due to continuous product improvement,
specifications are subject to change without notice.
Visit us on the web at www.york.com for the most
up-to-date technical information.
Additional rating information can be found at
www.ahridirectory.org
WARRANTY
Lifetime limited warranty on both heat exchangers to the original pur-
chaser; a 20-year limited warranty from original installation date to
subsequent purchaser.
10-year warranty on the heat exchanger in commercial applications.
Standard 5-year limited Parts warranty.
Extended 10-year limited parts warranty when product is regis-
tered online within 90 days of purchase for replacement or clos-
ing for new home construction.
EFFICIENCY
RATING
CERTIFIED
When paired with a
York heat pump
538513- YTG-A-0809
FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE
DESCRIPTION
These compact units employ induced combustion, reliable hot
surface ignition and high heat transfer aluminized tubular heat
exchangers. The units are factory shipped for installation in
upflow or horizontal applications and may be converted for
downflow applications.
These furnaces are designed for residential installation in a
basement, closet, alcove, attic, recreation room or garage and
are also ideal for commercial applications. All units are factory
assembled, wired and tested to assure safe dependable and
economical installation and operation.
These units are Category IV listed and may be vented either
through side wall or roof applications using approved plastic
combustion air and vent piping.
FEATURES
Modulating heating operation includes:
- Modulating gas valve, inducer and circulating blower
- Modulating operation from 100% to 35% input in 100
increments with nearly constant temperature rise.
Easily applied in upflow, horizontal left or right, or downflow
installation with minimal conversion necessary.
Compact, easy to install, ideal height 33" tall cabinet.
ECM variable speed drive for cooling SEER enhancement,
improved comfort with optional airflow delay profiles, and
continuous fan options for IAQ performance.
Easy access to controls to connect power/control wiring.
Built-in, high level self diagnostics with fault code display.
Low unit amp requirement for easy replacement application.
All models are convertable to use propane (LP) gas.
Electronic Hot Surface Ignition saves fuel cost with
increased dependability and reliability.
100% shut off main gas valve for extra safety.
24V, 40 VA control transformer and blower relay supplied for
add-on cooling.
Airflow leakage less than 1% of nominal airflow for
ductblaster conditions.
Solid removable bottom panel allows easy conversion.
Hi-tech tubular aluminized steel primary heat exchanger with
stainless steel tube/aluminum fin secondary heat exchanger
for outstanding efficiency.
No knockouts to deal with, making installation easier.
Movable duct connector flanges for application flexibility.
Quiet inducer operation, burner, and blower operation.
Inducer rotates for easy conversion of venting options.
Fully supported blower assembly for easy access and
removal of blower.
External air filters used for maximum flexibility in meeting
customers IAQ needs.
Insulated blower compartment for thermal and acoustic
performance.
1/4 turn knobs provided for easy independent door removal.
Internal condensate trap design (patent pending) provides
condensate management options, easy visual operation
check, and is self priming to prevent nuisance problems.
These models may be connected as part of a communicating
control system using a 4-wire connection bus.
The York YP9C modulating ECM furnace is part of a “Hybrid
Comfort System” when paired with a York Heat Pump.
Question and Answer IconNeed help?

Do you have a question about the York YP9C*C and is the answer not in the manual?

York YP9C*C Specifications

General IconGeneral
BrandYork
ModelYP9C*C
CategoryFurnace
LanguageEnglish

Summary

York Furnace Product Overview

Product Description

Details induced combustion, heat exchangers, installation types, and venting for York furnaces.

Key Product Features

Highlights modulating operation, ECM motor, ease of use, diagnostics, and hybrid system compatibility.

Filter Performance and Installation Clearances

Filter Performance Details

Explains airflow capacity data and filter requirements for York furnaces.

Recommended Filter Sizes

Lists recommended air filter sizes based on furnace CFM and cabinet size.

Unit Clearances to Combustibles

Specifies required clearances for furnace installation in various applications.

Furnace Accessories and Conversions

Propane (LP) Conversion Kit

Information on converting natural gas units to propane (LP) operation.

Venting Termination Kits

Details on sidewall and concentric vent termination kits for installation.

Filter Racks and Combustible Floor Bases

Information on filter racks and required bases for combustible floors.

EAC Transition Kits

Kits for integrating Electronic Air Cleaners (EAC) with furnace return airflow.

Blower Performance Data

Blower Performance CFM

Provides CFM data for all positions and cooling speeds with jumper settings.

Related product manuals