TECHNICAL GUIDE
MODELS: GY8S*UH / LY8S*UH
GAS-FIRED
HIGH EFFICIENCY SINGLE STAGE
UPFLOW/HORIZONTAL FURNACES
STANDARD & Low NOx
NATURAL GAS
40 - 130 MBH INPUT
Due to continuous product improvement, specifica-
tions are subject to change without notice.
Visit us on the web at www.york.com for the most
up-to-date technical information.
Additional information can be found at
www.gamanet.org.
EFFICIENCY
RATING
CERTIFIED
ISO 9001
Certified Quality
Management System
278436-YTG-A-0407
FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE
DESCRIPTION
These high efficiency, compact units employ induced com-
bustion, reliable hot surface ignition and high heat transfer
aluminized tubular heat exchangers. The units are factory
shipped for installation in upflow or horizontal applications.
These furnaces are designed for residential installation in a
basement, closet, alcove, attic, recreation room or garage
and are also ideal for commercial applications. All units are
factory assembled, wired and tested to assure safe depend-
able and economical installation and operation.
These units are Category I listed and may be common vented
with another gas appliance as allowed by the National Fuel
Gas Code.
WARRANTY
20-year limited warranty on the heat exchanger.
10-year heat exchanger warranty on commercial applica-
tions.
5-year limited parts warranty.
FEATURES
Easily applied in upflow, horizontal left or horizontal right
installation with no conversion necessary.
100% shut off main gas valve for added safety.
Rollout safety control.
Low unit amp requirement for easy application.
High quality inducer motor for quiet operation.
Built-in self diagnostics with fault code display.
Electronic Hot Surface Ignition saves fuel cost with
increased dependability and reliability.
Standard terminals for controlling humidifiers and EAC's.
40 VA control transformer fuse protected.
Easy to connect power and control wiring.
Efficiency ratings of 80 AFUE attained by using tubular
heat exchangers.
Cooling relay supplied for easy installation of add-on
cooling.
Multi-speed PSC, large, quiet direct-drive blower motor
to match cooling requirements.
Adjustable fan-off settings to eliminate “cold-blow”.
Compact 40-in height allows installation in small space
confines.
Low NOx models have been designed to meet specific
code requirements.
All models are propane convertible.
Question and Answer IconNeed help?

Do you have a question about the York GY8S*UH and is the answer not in the manual?

Summary

TECHNICAL GUIDE

DESCRIPTION

Details high efficiency, compact induced combustion furnaces for residential and commercial use.

WARRANTY

Outlines the limited warranty for heat exchanger and parts.

FEATURES

Lists key operational benefits like easy installation, safety controls, and diagnostics.

CABINET AND DUCT DIMENSIONS

Provides physical dimensions and duct connection information for various models.

RATINGS & PHYSICAL; ELECTRICAL DATA - UPFLOW MODELS

Presents input/output, airflow, electrical specs, and blower data for upflow configurations.

BLOWER PERFORMANCE CFM - UPFLOW (WITHOUT FILTER) - BOTTOM RETURN

Details blower airflow (CFM) at various speeds and static pressures for upflow models.

BLOWER PERFORMANCE CFM - UPFLOW (WITHOUT FILTER) - LEFT SIDE

Details blower airflow (CFM) at various speeds and static pressures for upflow models.

HORIZONTAL SIDEWALL VENTING

Covers horizontal sidewall venting requirements and approved methods.

FILTER PERFORMANCE

Provides pressure drop values for different filter types and airflow ranges.

Thermostat Chart

Illustrates connection diagrams for various thermostat and furnace control configurations.

Summary

TECHNICAL GUIDE

DESCRIPTION

Details high efficiency, compact induced combustion furnaces for residential and commercial use.

WARRANTY

Outlines the limited warranty for heat exchanger and parts.

FEATURES

Lists key operational benefits like easy installation, safety controls, and diagnostics.

CABINET AND DUCT DIMENSIONS

Provides physical dimensions and duct connection information for various models.

RATINGS & PHYSICAL; ELECTRICAL DATA - UPFLOW MODELS

Presents input/output, airflow, electrical specs, and blower data for upflow configurations.

BLOWER PERFORMANCE CFM - UPFLOW (WITHOUT FILTER) - BOTTOM RETURN

Details blower airflow (CFM) at various speeds and static pressures for upflow models.

BLOWER PERFORMANCE CFM - UPFLOW (WITHOUT FILTER) - LEFT SIDE

Details blower airflow (CFM) at various speeds and static pressures for upflow models.

HORIZONTAL SIDEWALL VENTING

Covers horizontal sidewall venting requirements and approved methods.

FILTER PERFORMANCE

Provides pressure drop values for different filter types and airflow ranges.

Thermostat Chart

Illustrates connection diagrams for various thermostat and furnace control configurations.

Overview

This document describes the YORK GY8S*UH / LY8S*UH series of gas-fired, high-efficiency, single-stage upflow/horizontal furnaces, available in standard and Low NOx models, with natural gas input ranging from 40 to 130 MBH.

Function Description

These furnaces are designed for residential and commercial heating applications. They utilize induced combustion, reliable hot surface ignition, and high heat transfer aluminized tubular heat exchangers to achieve high efficiency. The units are factory-shipped for installation in upflow or horizontal configurations and are suitable for basements, closets, alcoves, attics, recreation rooms, or garages. They are Category I listed, allowing for common venting with other gas appliances as per the National Fuel Gas Code.

Important Technical Specifications

  • Efficiency: 80 AFUE (Annual Fuel Utilization Efficiency) as determined by DOE Test procedures.
  • Input/Output: Ranges from 40 MBH input (32 MBH output) to 130 MBH input (104 MBH output).
  • Airflow: Nominal airflow ranges from 1200 CFM to 2200 CFM.
  • Cabinet Widths: Available in 14-1/2", 17-1/2", 21", and 24-1/2" widths.
  • Total Unit Amps: Ranges from 9.0 to 14.0 amps.
  • Air Temp Rise: Ranges from 25-55°F to 40-70°F, depending on the model.
  • Max Outlet Air Temp: Ranges from 155°F to 170°F.
  • Blower Motor: PSC (Permanent Split Capacitor) type, with horsepower ranging from 1/2 to 1.0 HP.
  • Blower Amps: Ranges from 7.1 to 14.0 amps.
  • Max Over-Current Protect: 20 amps for all models.
  • Min. Wire Size (awg) @ 75 ft one way: 12 or 14 AWG.
  • Weight: Ranges from 105 LBS to 158 LBS.
  • Dimensions: Height is 40 inches for all models. Widths (A) range from 14-1/2" to 24-1/2". Depths (B) range from 13-1/4" to 23-1/4".
  • Vent Connections: 4" diameter.
  • Gas Inlet: 1-1/4" x 2-1/2".
  • Power Wiring: 7/8" hole.
  • T'stat Wiring: 7/8" K.O.
  • Clearances to Combustibles:
    • Upflow: Top 1", Front 6", Rear 0", Left Side 0", Right Side 3", Flue 6". Floor/Bottom: Combustible.
    • Upflow B-Vent: Top 1", Front 3", Rear 0", Left Side 0", Right Side 0", Flue 1". Floor/Bottom: Combustible.
    • Horizontal: Top 1", Front 6", Rear 0", Left Side 0", Right Side 3", Flue 6". Floor/Bottom: Combustible.
    • Horizontal B-Vent: Top 1", Front 3", Rear 0", Left Side 0", Right Side 0", Flue 1". Floor/Bottom: Combustible.
    • Note: Line contact is permitted for horizontal installations between the rear panel/side panel intersection and building joists/studs/framing.

Usage Features

  • Installation Flexibility: Easily applied in upflow, horizontal left, or horizontal right installations without conversion.
  • Hot Surface Ignition: Electronic Hot Surface Ignition enhances dependability and fuel cost savings.
  • Multi-speed Blower: PSC direct-drive blower motor with multiple speeds to match cooling requirements.
  • Adjustable Fan-Off Settings: Eliminates "cold-blow" by allowing adjustment of the fan-off delay.
  • Compact Design: 40-inch height facilitates installation in confined spaces.
  • Low NOx Models: Designed to meet specific code requirements.
  • Propane Convertible: All models can be converted to propane (LP) operation using an accessory conversion kit (1NP0347). This conversion must be performed by qualified personnel.
  • Horizontal Sidewall Venting: Approved for use with auxiliary power vents (Fields Controls Model SWG-4Y or Tjernlund Model GPAK-JT) for applications where vertical venting is not possible. Requires 4" (10.2 cm) diameter pipe with a minimum length of 4.5 feet (1.37 m) and a maximum length of 34.5 feet (10.82 m) with up to 4 elbows.
  • Thermostat Compatibility: A wide selection of compatible thermostats is available, including manual change-over electronic non-programmable, auto/manual changeover electronic programmable (deluxe 7-day), and auto/manual changeover electronic programmable. Standard terminals are provided for controlling humidifiers and EACs.
  • High Altitude Pressure Switches: Not required for altitudes less than 8,000 feet. Kits are available for altitudes above 8,000 feet (1PS0301 for 40, 60 MBH; 1PS0302 for 80 MBH; 1PS0311 for 100, 115, 130 MBH). Conversion must be performed by qualified personnel.

Maintenance Features

  • Self-Diagnostics: Built-in self-diagnostics with fault code display for easier troubleshooting.
  • Fuse Protected Transformer: 40 VA control transformer is fuse protected for enhanced safety.
  • Rollout Safety Control: Included for added safety.
  • 100% Shut-Off Main Gas Valve: Ensures added safety by completely shutting off the gas supply.
  • Filter Performance: The unit's performance is rated without filters. Filter pressure drop values are provided for disposable, washable fiber, and pleated filters to help determine system airflow with a filter in place. Recommended filter sizes are provided based on CFM and cabinet size. Air velocity through throwaway filters should not exceed 300 feet per minute. Airflows above 1800 CFM require return from two sides or one side plus bottom.
  • Low Unit Amp Requirement: Simplifies application.
  • High Quality Inducer Motor: Designed for quiet operation.

York GY8S*UH Specifications

General IconGeneral
BrandYork
ModelGY8S*UH
CategoryFurnace
LanguageEnglish

Related product manuals