TECHNICAL GUIDE
80 AFUE
MULTI-POSITION
GAS FURNACES
MODELS: G8C SERIES
4-POSITION
50-125 MBH INPUT
3-POSITION
150 MBH INPUT
EFFICIENCY
RATING
CERTIFIED
ISO 9001
Certified Quality
Management System
270844-YTG-A-0407
FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE
®
DESCRIPTION
These compact units (31-1/2" high) employ induced combus-
tion, reliable electronic ignition and high heat transfer heat
exchangers. The units may be factory shipped for upflow/hor-
izontal application and converted for downflow application.
These units may also be factory shipped for downflow appli-
cation and converted for upflow/horizontal applications
Note: The 150 MBH input model is upflow/horizontal only and
may not be converted to the downflow position.
These furnaces are designed for residential installation in a
basement, closet, alcove, attic, or garage. All units are factory
assembled, wired and tested to assure safe dependable and
economical installation and operation.
These units are Category I listed and may be common vented
with another gas appliance as allowed by the National Fuel
Gas Code.
WARRANTY
20-year limited warranty on the heat exchanger.
5-year limited parts warranty.
FEATURES
4-position (MU) upflow models allow horizontal-left, hori-
zontal-right, downflow and convertible applications
4-position (MD) models allow downflow and convertible
upflow/horizontal applications
3-position (UH) 150 MBH input model allows upflow, hori-
zontal-left and horizontal-right application
Reliable, hot surface ignitor
Integrated control module for simplicity and reliable, eco-
nomical operation
Built-in self-diagnostics with fault code display
100% shut off main gas valve for added safety
Rollout safety control
Low unit amp requirement for easy application
High quality inducer motor for quiet operation
40 VA, fuse protected control transformer
Terminals for controlling humidifiers and EAC’s
Easy to connect power and control wiring
Efficiency ratings of 80 AFUE
Cooling blower relay supplied for easy installation of add-
on cooling
Blower off-delay for cooling SEER improvement
Multi-speed PSC, direct-drive blower motors to match
cooling requirements
Adjustable fan-off settings to eliminate "cold-blow"
Compact 31-1/2-in height allows installation in small space
confines
All models are propane convertible with factory kit
Pre-painted exterior provides attractive, durable finish
Models are not approved for LoNox applications
Question and Answer IconNeed help?

Do you have a question about the York G8C05012(MU,MD)B12 and is the answer not in the manual?

York G8C05012(MU,MD)B12 Specifications

General IconGeneral
ModelG8C05012(MU, MD)B12
TypeGas Furnace
Efficiency Rating80% AFUE
Blower TypeMulti-speed
Fuel TypeNatural Gas
Installation TypeUpflow/Horizontal
Blower MotorPSC
Gas ValveSingle Stage
Heat ExchangerAluminized steel
Weight120 lbs
Heating Capacity50, 000 BTU
IgnitionHot surface
Vent Size4 inches

Summary

Technical Guide

80 AFUE Multi-Position Gas Furnaces

Overview of 80 AFUE multi-position gas furnaces for residential use.

Models: G8C Series

Details the specific G8C Series models covered in this guide.

4-Position 50-125 MBH Input

Information on 4-position furnaces with 50-125 MBH input capacity.

3-Position 150 MBH Input

Details for 3-position furnaces with 150 MBH input capacity.

Product Description

Warranty Information

Heat Exchanger Warranty

Details the 20-year limited warranty period for the heat exchanger.

Limited Parts Warranty

Covers the 5-year limited warranty for furnace parts.

Key Features

Multi-Position Capabilities

Details on 4-position and 3-position configurations for various airflow directions.

Operational and Safety Features

Highlights reliable ignition, integrated control, safety features, and self-diagnostics.

Installation and Electrical Features

Covers low amp draw, quiet motor, control transformer, and wiring terminals.

Blower and Efficiency Features

Details blower capabilities, efficiency, and cooling-related features.

Design and Compatibility Features

Notes compact size, propane convertibility, finish, and LoNox limitations.

Cabinet and Duct Dimensions

Ratings and Electrical Data (Upflow Models)

Blower Performance (Upflow)

Upflow Single Side Return Blower Performance

Blower performance data for upflow configurations with single side return.

Dual Return Blower Performance

Blower performance data for dual return (two sides or one-side & bottom) configurations.

Blower Performance (Continued)

Bottom/End Return Blower Performance

Blower performance data for bottom/end return configurations.

Return Air and Filters

Filter Performance

Information on pressure drop for various filter types and airflow ranges.

Recommended Filter Sizes

Upflow Recommended Filter Sizes

Recommended filter sizes for upflow configurations by model.

Downflow Recommended Filter Sizes

Recommended filter sizes for downflow configurations by model.

Applying Filter Pressure Drop to Determine System Airflow

Unit Clearances to Combustibles

Accessories

Propane Conversion Kit (Standard)

Accessory for converting natural gas units to propane (LP) at altitudes 0-2,000 ft.

Propane Conversion Kit (High Altitude)

Accessory for converting natural gas units to propane (LP) at altitudes 2,000-8,000 ft.

Natural Gas Conversion Kit (High Altitude)

Accessory for converting units for high altitude natural gas operation at 2,000-8,000 ft.

Combustible Floor Base

Accessory for downflow applications on combustible surfaces.

Bottom External Filter Rack

Accessory for upflow/bottom return air applications.

Related product manuals