TECHNICAL GUIDE
80% MODULATING (PSC MOTOR)
GAS-FIRED RESIDENTIAL
MULTI-POSITION GAS FURNACES
STANDARD & Low NOx MODELS
MODELS: YM8M / YMLM
NATURAL GAS
60 - 120 MBH INPUT
Due to continuous product improvement, specifications
are subject to change without notice.
Visit us on the web at www.york.com
Additional rating information can be found at
www.ahridirectory.org
WARRANTY
Lifetime limited warranty on heat exchanger to the original purchaser; a
20-year limited warranty from original installation date to subsequent
purchaser.
10-year warranty on the heat exchanger in commercial applications.
Standard 5-year limited parts warranty.
Extended 10-year limited parts warranty when product is regis-
tered online within 90 days of purchase for replacement or closing
for new home construction.
EFFICIENCY
RATING
CERTIFIED
ISO 9001
Certified Quality
Management System
402695-YTG-C-0409
FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE
DESCRIPTION
These compact units employ induced combustion, reliable hot
surface ignition and high heat transfer aluminized tubular heat
exchangers. The units are factory shipped for installation in
upflow or horizontal applications and may be converted for
downflow applications.
These furnaces are designed for residential installation in a
basement, closet, alcove, attic, recreation room or garage and
are also ideal for commercial applications. All units are factory
assembled, wired and tested to assure safe dependable and
economical installation and operation.
These units are Category I listed and may be common vented
with another gas appliance as allowed by the National Fuel Gas
Code.
FEATURES
Modulating heating operation includes:
- Modulating gas valve, inducer and circulating blower.
- Modulating operation from 100% input to 50% input in 1%
increments.
Easily applied in upflow, horizontal left or right, or downflow
installation with minimal conversion necessary.
Compact, easy to install, ideal height 33" tall cabinet.
Blower-off delay for cooling SEER improvement.
Easy access to controls to connect power/control wiring.
Built-in, high level self diagnostics with fault code display.
Low unit amp requirement for easy replacement application.
All models are convertable to use propane (LP) gas.
Electronic Hot Surface Ignition saves fuel cost with
increased dependability and reliability.
100% shut off main gas valve for extra safety.
High-efficiency variable speed direct drive motor.
24V, 40 VA control transformer and blower relay supplied for
add-on cooling.
Hi-tech tubular aluminized steel primary heat exchanger.
Blower door safety switch.
Solid removable bottom panel allows easy conversion.
Low NOx models have been designed to meet specific code
requirements.
Airflow leakage less than 1% of nominal airflow for
ductblaster conditions.
No knockouts to deal with, making installation easier.
Movable duct connector flanges for application flexibility.
Quiet inducer, burner and blower operation.
Inducer rotates for easy conversion of venting options.
Fully supported blower assembly for easy access and
removal of blower.
External air filters used for maximum flexibility in meeting
customers IAQ needs.
Venting applications - may be installed as a common vent
with other gas-fired appliances.
Insulated blower compartment for thermal and acoustic
performance.
1/4 turn knobs provided for easy door removal.
Question and Answer IconNeed help?

Do you have a question about the York YM8M060A12MP11 and is the answer not in the manual?

York YM8M060A12MP11 Specifications

General IconGeneral
ModelYM8M060A12MP11
Heating Capacity60, 000 BTU
AFUE Rating80%
Weight120 lbs
Fuel TypeNatural Gas
Gas TypeNatural Gas
Vent Diameter4 inches

Summary

Product Description and Features

Unit Description

Details the compact units employing induced combustion, reliable hot surface ignition, and high heat transfer tubular heat exchangers.

Key Unit Features

Highlights modulating heating, easy installation, diagnostics, propane conversion, safety, and efficiency.

Cabinet and Duct Dimensions

Cabinet Dimensions and Weights

Provides a table with cabinet dimensions (A, B, C) and approximate operating weights for different models.

Ratings and Physical Data

Lists input/output MBH, AFUE, airflow, unit amps, and blower specifications for each model.

Filter Performance and Clearances

Filter Performance Recommendations

Explains airflow capacity without filters and requirements for field-installed air filters.

Unit Clearances to Combustibles

Specifies required clearances for upflow, downflow, and horizontal installations.

Available Accessories

Lists conversion kits, filter racks, floor base kits, and thermostat options.

Blower Performance Data

Bottom Airflow Return Performance

Details blower airflow (SCFM) at various static pressures for bottom return.

Upflow Airflow Return Performance

Provides blower airflow (SCFM) for upflow configurations at different static pressures.

Related product manuals