2 Johnson Controls Unitary Products
402695-YTG-C-0409
Annual Fuel Utilization Efficiency (AFUE) numbers are determined in accordance with DOE Test procedures.
Wire size and over current protection must comply with the National Electrical Code (NFPA-70-latest edition) and all local codes.
LEFT SIDE
RIGHT SIDE
.5”
.5”
RETURN END
B
24.25”
30.25”
28.5”
Gas Pipe
Entry
Thermostat
Wiring
FRONT
14”
1”
1.5”
23”
SUPPLY END
C
24.38”
20”
.5”
B
Gas Pipe
Entry
Thermostat
Wiring
33”
A
.5”
Electrical
Entry
Electrical
Entry
Vent Connection
Outlet
Vent
Connection
Outlet
4” Diameter
Outlet
Vent Connection
Cabinet and Duct Dimensions
Models
Nominal
CFM (m
3
/min)
Cabinet
Size
Cabinet Dimensions (Inches)
Approximate
Operating Weights
A B C Lbs
YM(8,L)M060A12MP11 1200 A 14 1/2 13 1/4 10.3 94
YM(8,L)M080B12MP11 1200 B 17 1/2 16 1/4 11.8 103
YM(8,L)M080C16MP11 1600 C 21 19 3/4 13.6 114
YM(8,L)M100C16MP11 1600 C 21 19 3/4 13.6 118
YM(8,L)M100C20MP11 2000 C 21 19 3/4 13.6 122
YM(8,L)M120C20MP11 2000 C 21 19 3/4 15.8 129
Ratings & Physical / Electrical Data
Models
Input
Max/Min
Output
Max/Min
AFUE
Nominal
Airflow
Total
Unit
Amps
Air Temp.
Rise Max
Input
Air Temp.
Rise Min
Input
MBH MBH CFM °F °F
YM(8,L)M060A12MP11 60/30 47/24 80.0 1200 7.0 35-65 20-50
YM(8,L)M080B12MP11 80/40 62/32 80.0 1200 7.5 40-70 20-50
YM(8,L)M080C16MP11 80/40 62/32 80.0 1600 10.0 40-70 20-50
YM(8,L)M100C16MP11 100/50 78/40 80.0 1600 10.0 40-70 20-50
YM(8,L)M100C20MP11 100/50 78/40 80.0 2000 17.0 35-65 20-50
YM(8,L)M120C20MP11 120/60 95/48 80.0 2000 17.0 45-75 25-55
Models
Max.
Outlet
Air Temp
Blower
Blower
Wheel
size
Max
Over-Current
Protect
Min. wire Size
(awg) @ 75 ft
one way
°F HP Amps
YM(8,L)M060A12MP11 165 1/3 4.8 11 x 8 15 14
YM(8,L)M080B12MP11 170 1/3 4.8 11 x 8 15 14
YM(8,L)M080C16MP11 170 1/2 7.5 11 x 10 15 14
YM(8,L)M100C16MP11 170 1/2 7.5 11 x 10 15 14
YM(8,L)M100C20MP11 165 1 14.5 11 x 11 20 12
YM(8,L)M120C20MP11 175 1 14.5 11 x 11 20 12