Unitary Products Group 3
Annual Fuel Utilization Efficiency (AFUE) numbers are determined in accordance with DOE Test procedures.
Wire size and over current protection must comply with the National Electrical Code (NFPA-70-latest edition) and all local codes.
The furnace shall be installed so that the electrical components are protected from water.
RATINGS & PHYSICAL / ELECTRICAL DATA - UPFLOW MODELS
Models
Input Output
Nominal
Airflow
Cabinet Width
Total Unit Amps
AFUE Air Temp. Rise
MBH MBH CFM In. % °F
PS8A12(N,L)040UH11 40 32 1200 14-1/2 9.0 80.0 25-55
PS8A12(N,L)060UH11 60 48 1200 14-1/2 9.0 80.0 25-55
PS8A12(N,L)080UH11 80 64 1200 14-1/2 9.0 80.0 35-65
PS8B16(N,L)080UH11 80 64 1600 17-1/2 12.0 80.0 25-55
PS8C22N080UH11
PS8C20L080UH11
80 64 2200 21 14.0 80.0 25-55
PS8B12(N,L)100UH11 100 80 1200 17-1/2 12.0 80.0 40-70
PS8B16(N,L)100UH11 100 80 1600 17-1/2 12.0 80.0 35-65
PS8C20(N,L)100UH11 100 80 2000 21 14.0 80.0 25-55
PS8C16N115UH11 115 92 1600 21 12.0 80.0 35-65
PS8C20(N,L)115UH11 115 92 2000 21 14.0 80.0 30-60
PS8D20(N,L)130UH11 130 104 2000 24-1/2 14.0 80.0 35-65
Models
Max. Outlet
Air Temp
Blower Blower Size
Max
Over-Current
Protect
Min. wire Size
(awg) @ 75 ft
one way
Operation
Weight
°F Hp Amps In. LBS
PS8A12(N,L)040UH11 155 1/2 7.1 10 x 8 20 14 105
PS8A12(N,L)060UH11 155 1/2 7.1 10 x 8 20 14 110
PS8A12(N,L)080UH11 170 1/2 7.1 10 x 8 20 14 117
PS8B16(N,L)080UH11 155 3/4 11.5 11 x 8 20 14 126
PS8C22N080UH11
PS8C20L080UH11
165 1.0 14.0 11 x 11 20 12 140
PS8B12(N,L)100UH11 170 1/2 7.1 10 x 8 20 14 128
PS8B16(N,L)100UH11 165 3/4 11.5 11 x 8 20 14 134
PS8C20(N,L)100UH11 155 1.0 14.0 11 x 11 20 12 145
PS8C16N115UH11 170 3/4 11.5 10 x 10 20 14 145
PS8C20(N,L)115UH11 170 1.0 14.0 11 x 11 20 12 147
PS8D20(N,L)130UH11 165 1.0 14.0 11 x 11 20 12 158