Johnson Controls Unitary Products 33
923178-UTG-B-0114
13. Remove compressor
14. Remove isolation sheet
15. Remove support plate of condenser
16. Remove chassis and condenser
STEPS PROCEDURES
Compressor
Twist off the 3 foot nuts on
compressor and then remove
the compressor.
Isolation
Sheet
Twist off the screws connecting
isolation sheet and end plate of
condenser and chassis, and then
remove the isolation sheet.
Condenser
Chassis
Pull it upwards to separate
the chassis and condenser.