Johnson Controls Unitary Products 21
923212-UTG-A-0113
14. Remove pipe-stopping plate
15. Remove damping board
16. Remove evaporator
17. Remove the fixing plate of motor
STEPS PROCEDURES
Pipe-Stopping Plate
Screw
Remove two screws on pipe-stopping
plate for indoor unit, and then remove
the pipe-stopping
Screw
Damping
Board
Remove 2 screws on
damping board, and then
remove the damping board.
Screw
Evaporator
a. Remove screws between
evaporator and bottom case.
b. Turn over the indoor unit
and adjust the pipe line to
the position as shown by
the broken line.
c. Lift up the evaporator, and
then remove the evaporator.
Screw
Remove 2 screws on fixing
plate of motor, and then
remove the fixing pate of
motor.

Related product manuals