LX SERIES
DUCTLESS MULTI-ZONE SPLIT
HEAT PUMPS
16 SEER – 1 PHASE
1.5 THRU 3.5 NOMINAL TONS
MODELS:
INDOOR-DHPM/OUTDDOR-DHMF
Due to continuous product improvement, specifications
are subject to change without notice.
Visit us on the web at
www.upgnet.com
Additional rating information can be found at
www.ahridirectory.org
WARRANTY SUMMARY*
Standard 2-Years limited parts warranty.
Standard 6-Years limited compressor warranty.
TECHNICAL
GUIDE
TECHNICAL
GUIDE
FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE
923212-UTG-A-0113
DESCRIPTION
The Multi Zone Series are ductless climate systems. They are designed
with a matching indoor unit for optimum performance and efficiency.
These climate systems are supported with accessories and documents
to serve specific functions.
FEATURES
Variable Frequency Rotary Compressor - Twin rotary inverter compressor
on all models features high efficiency operation that modulates down to 15
Hz and as high as 120 Hz for reduced vibration and quiet operation. Brush-
less DC motor uses powerful Neodymium magnets that are approximately
15-20 times stronger than ferrite magnets used in conventional AC compres-
sors. The DC Inverter Control provides continuous operation, while adjusting
capacity according to room temperature. The accurate sensing of cooling or
heating loads prevents frequent changes in capacity and ensures efficient,
economical operation.
Low Ambient Cooling Operation Down to 5 °F - This feature allows for a
space to be air-conditioned even in outdoor temperatures as low as 5 °F.
This cooling ability is important when dealing with server equipment rooms,
surveillance mechanical rooms, restaurant kitchens, fitness centers, and
more.
Condenser High Temperature Protection - The outdoor coil thermistor
continuously monitors the temperature and communicates with the micro-
processor. Depending on the temperature measured, the compressor will be
allowed to increase the frequency if needed to meet the load or is forced to
run at the current or reduced frequency. If the temperature gets excessively
high the compressor will be de-energized.
High Pressure Discharge Temperature - The compressor discharge line
thermistor continuously monitors the temperature and communicates with
the microprocessor. Depending on the temperature measured, the compres-
sor will be allowed to increase the frequency to meet the load or is forced to
run at the current or reduced frequency. If the temperature gets excessively
high, the compressor will be de-energized.
Defrost Control (Heat Pump Models) - Defrost cycle is automatically
enabled if there is a build-up of frost on the outdoor coil. Outdoor fan and
indoor blower operation is terminated during the defrost cycle. H1 is dis-
played on the indoor unit panel on the front cover during a defrost cycle.
Reversing Valve (Heat Pump Models) - 4-way interchange reversing valve
effects a rapid change in direction of refrigerant flow resulting in quick
changeover from cooling to heating and vice versa. Valve operates on sys-
tem pressure differential between outdoor unit and indoor unit.
R-410A Refrigerant - Unit is pre-charged with R410A refrigerant that uses
PVE refrigerant oil. Polyvinylether (PVE) is an innovative refrigerant oil spe-
cially formulated for hydrofluorocarbon (HFC) refrigeration systems. In addi-
tion to providing lubricating properties, it also has a number of other applied
advantages that help to increase the reliability of the refrigeration systems
where it is applied.
Refrigerant Line Connections, Service Valve - Outdoor units are
designed with easy service and maintenance in mind. Maintenance points
are located behind easy-access panels, to make installation and service a
breeze for a trained technician. Flare connection lines are located on side of
unit cabinet. Fully serviceable brass service valve prevents corrosion and
provide access to refrigerant system. Shut-off valve that can be fully shut off
while 2-way service valve (with service port) may be front seated to manage
refrigerant charge while servicing system.
Air Deflection Louvers - Horizontal louvers default to the cooling or heating
position when the unit is operating. Horizontal louvers can be set to a preset
oscillating range or fixed position from the wireless remote control. Full oscil-
lating is the default setting when button is pushed. Vertical louvers can be
manually adjusted to direct the airflow for optimal comfort.
Indoor Coil Freeze Protection - The indoor coil thermistor monitors the coil
temperature continuously. Any time the coil temperature drops below 30°F,
the compressor and the outdoor fan (30 seconds later) will be switched off
until the coil temperature rises above 43°F and the compressor has been off
for a minimum of 3 minutes.
I FEEL Function - When I FEEL is activated, the system will satisfy your
cooling or heating temperature setpoint where the remote control is located.
When I FEEL is deactivated, the system will satisfy the cooling or heating
temperature setpoint where the indoor unit is located. This feature provides
homeowners with optimum comfort whether they are near or far from the
indoor unit.
Hot Heat Pump (cold air prevention) - In heating mode, the indoor fan will
be delayed from 1 to 3 minutes to allow refrigerant to warm up and avoid
cold blow. This may occur during:
Initial start-up of a heating cycle
Immediately after completion of an Auto mode operation
Heating under extremely low indoor temperatures
Question and Answer IconNeed help?

Do you have a question about the York DHPM09NWM42Q1 and is the answer not in the manual?

York DHPM09NWM42Q1 Specifications

General IconGeneral
BrandYork
ModelDHPM09NWM42Q1
CategoryAir Conditioner
LanguageEnglish

Summary

DESCRIPTION

System Overview

The Multi Zone Series are ductless climate systems designed for optimum performance.

FEATURES

Compressor and Operational Features

Variable rotary compressor, low ambient cooling, protection, defrost, reversing valve.

Airflow and System Control

Air deflection louvers, indoor coil freeze protection, I FEEL function, hot heat pump.

Refrigerant and Connectivity

R-410A refrigerant and refrigerant line connections.

MODEL NOMENCLATURE

Understanding Model Codes

Explains the coding system for unit models, including type, SEER, capacity, and features.

TECHNICAL SPECIFICATIONS

Performance Metrics

Details cooling and heating performance ratings, SEER, EER, and HSPF for various models.

Indoor Unit Specs and Dimensions

Provides physical dimensions, fan specs, and coil details for indoor units.

OUTDOOR UNIT SPECIFICATIONS

Performance Data

Details compressor, fan, refrigerant charge, and electrical specs for outdoor units.

Dimensions and Ratings

Lists physical dimensions, weights, and pipe/gas line sizes for outdoor units.

OPERATION CHARACTERISTIC CURVES

18K Model Curves

Shows current vs. compressor speed curves for cooling and heating for the 18K model.

24K/30K Model Curves

Shows current vs. compressor speed curves for cooling and heating for the 24K/30K models.

CAPACITY VARIATION RATIO

42K Model Variation

Capacity variation ratio vs. outdoor temperature for cooling and heating.

18K, 24K/30K Models Variation

Capacity variation ratio vs. outdoor temperature for cooling and heating.

OPERATION DATA

Cooling and Heating Operating Conditions

Provides temperature, pressure, and fan/compressor modes for cooling and heating.

Indoor Unit Sound Levels

Details sound pressure levels for different fan speeds of indoor units.

OUTDOOR UNIT NOISE LEVELS

18K/24K/30K Unit Noise

Outdoor side noise levels vs. compressor frequency for 18K, 24K, and 30K units.

42K Unit Noise

Outdoor side noise levels vs. compressor frequency for the 42K unit.

CONSTRUCTION DIMENSIONS

Indoor Unit Dimensions and Weight

Provides A, B, C dimensions and gross weight for indoor units.

Outdoor Unit Dimensions and Weight

Provides A, B, C dimensions and gross weight for outdoor units.

REFRIGERANT SYSTEM

System Diagram Overview

Illustrates the refrigerant flow and components within the multi-zone system.

WIRING DIAGRAMS

Electrical Data and Symbols

Lists electrical symbols and their corresponding wire colors and part names for indoor/outdoor units.

ELECTRICAL WIRING SCHEMATICS

18K and 24K Outdoor Unit Wiring

Provides wiring diagrams for 18K and 24K outdoor heat pumps.

ELECTRICAL WIRING SCHEMATICS (Continued)

30K and 42K Outdoor Unit Wiring

Provides wiring diagrams for 30K and 42K outdoor heat pumps.

CONTROL OPERATIONS

System Basic Functions

Details cooling, heating, and dry modes, including fan operation and oil return.

Fan Mode Operation

Describes system behavior when only the fan is operating, excluding compressor and 4-way valve.

Protection Functions Overview

Outlines various protection mechanisms like mode conflict, overload, and communication faults.

SENSOR INFORMATION

Sensor Fault Descriptions

Lists sensor designations and the faults detected for each.

RESISTANCE TABLES

Ambient Temperature Sensor Resistance (15K)

Provides resistance values for ambient sensors across various temperatures.

RESISTANCE TABLES (Continued)

Tube Temperature Sensor Resistance (20K)

Provides resistance values for tube temperature sensors across various temperatures.

RESISTANCE TABLES (Continued)

Discharge Temperature Sensor Resistance (50K)

Provides resistance values for outdoor discharge temperature sensors.

DISASSEMBLY PROCEDURES

Indoor Unit Disassembly

Covers removal of panels, filters, displays, covers, and internal components like evaporator and motor.

Outdoor Unit Disassembly

Covers removal of covers, grille, panels, handles, electric box, and major components like compressor and condenser.

Related product manuals