The Multi Zone Series are ductless climate systems designed for optimum performance.
Variable rotary compressor, low ambient cooling, protection, defrost, reversing valve.
Air deflection louvers, indoor coil freeze protection, I FEEL function, hot heat pump.
R-410A refrigerant and refrigerant line connections.
Explains the coding system for unit models, including type, SEER, capacity, and features.
Details cooling and heating performance ratings, SEER, EER, and HSPF for various models.
Provides physical dimensions, fan specs, and coil details for indoor units.
Details compressor, fan, refrigerant charge, and electrical specs for outdoor units.
Lists physical dimensions, weights, and pipe/gas line sizes for outdoor units.
Shows current vs. compressor speed curves for cooling and heating for the 18K model.
Shows current vs. compressor speed curves for cooling and heating for the 24K/30K models.
Capacity variation ratio vs. outdoor temperature for cooling and heating.
Capacity variation ratio vs. outdoor temperature for cooling and heating.
Provides temperature, pressure, and fan/compressor modes for cooling and heating.
Details sound pressure levels for different fan speeds of indoor units.
Outdoor side noise levels vs. compressor frequency for 18K, 24K, and 30K units.
Outdoor side noise levels vs. compressor frequency for the 42K unit.
Provides A, B, C dimensions and gross weight for indoor units.
Provides A, B, C dimensions and gross weight for outdoor units.
Illustrates the refrigerant flow and components within the multi-zone system.
Lists electrical symbols and their corresponding wire colors and part names for indoor/outdoor units.
Provides wiring diagrams for 18K and 24K outdoor heat pumps.
Provides wiring diagrams for 30K and 42K outdoor heat pumps.
Details cooling, heating, and dry modes, including fan operation and oil return.
Describes system behavior when only the fan is operating, excluding compressor and 4-way valve.
Outlines various protection mechanisms like mode conflict, overload, and communication faults.
Lists sensor designations and the faults detected for each.
Provides resistance values for ambient sensors across various temperatures.
Provides resistance values for tube temperature sensors across various temperatures.
Provides resistance values for outdoor discharge temperature sensors.
Covers removal of panels, filters, displays, covers, and internal components like evaporator and motor.
Covers removal of covers, grille, panels, handles, electric box, and major components like compressor and condenser.