EasyManua.ls Logo

York DHPM12NWM42Q1 - Page 25

York DHPM12NWM42Q1
30 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Johnson Controls Unitary Products 25
923212-UTG-A-0113
7. Remove electric box (Continued)
8. Remove left side plate
9. Remove axial flow blade
STEPS PROCEDURES
b. Twist off the screws on electric box,
cut off the tieline with scissors or pliers,
pull out the wiring terminal, pull it upwards
to remove the electric box.
Electric Box
Electric Box 1
c. Twist off the screws between electric box 1
and left side plate with screwdriver,
pull it upwards to remove the electric box 1.
Left Side Plate
Twist off the screws connecting the
left side plate and chassis with
screwdriver, and then remove the
left side plate.
Axial Flow Blade
Twist off the nuts on blade
with wrench and then remove
the axial flow blade.

Related product manuals