036-21342-002 Rev. E (0505)
8 Unitary Products Group
HEATING CAPACITY - Variable Speed Air Handler
UNIT
MODEL
N1VS AIR HANDLER
COIL MODEL
1
1. G2FD coils available with a factory installed horizontal drain pan. See price pages for specific model number.
HEATING
MODEL
ELECTRIC
HEAT KW
2
2. Single phase units require single phase 2HK heaters.
W
STAGE
(# CYL)
RATED
CFM
NET MBH
HSPF COP@ 47
47 OD 17 OD
E4TS030
N1VSB12 5,7.5,10,15,18 17 G2FD046S17
1 630 13400 3.80
2 630 24600 14400 8.7 3.48
2 1050 26400 15400 9.0 3.60
N1VSC16 5,7.5,10,15,20 21
G2FD042S21
1 650 13200 3.80
2 650 24200 14200 8.7 3.46
2 1065 26000 15200 9.0 3.58
G2FD048S21
1 650 13800 3.88
2 650 24800 14800 8.9 3.52
2 1065 27000 16000 9.2 3.64
E4TS036
N1VSC16 5,7.5,10,15,20 21 G2FD048S21
1 770 19600 3.78
2 770 31600 19000 8.7 3.52
2 1185 35000 20800 9.2 3.54
N1VSD20 7.5,10,15,20,25,30 24 G2FD048S24
1 780 20000 3.86
2 780 32000 19200 8.8 3.62
2 1200 35600 21200 9.3 3.74
E4TS048
F(2,3)FV060 10,15,20,25
24
1 1040 23800 3.66
2 1040 43500 24800 8.2 3.50
2 1600 47000 26400 8.5 3.58
N1VSD20 7.5,10,15,20,25,30
G2FD060S24
1 1040 23800 3.66
2 1040 43500 24800 8.2 3.50
2 1605 47000 26400 8.5 3.58
G2FD061H24
1 1040 24200 3.72
2 1040 44500 25600 8.4 3.58
2 1605 48000 27000 8.7 3.66
E4TS060
F(2,3)FV060 10,15,20,25
24
1 1220 25800 3.58
2 1220 51000 26400 8.1 3.32
2 1875 54000 28600 8.5 3.44
N1VSD20 7.5,10,15,20,25,30
G2FD060S24
1 1200 25800 3.58
2 1200 51000 26400 8.1 3.32
2 1860 54000 28600 8.5 3.44
G2FD061H24
1 1200 26600 3.64
2 1200 50500 26800 8.3 3.38
2 1860 55000 29200 8.7 3.50