FULL-CASED MULTI-POSITION FOR
COOLING/HEAT PUMPS
MODELS: MC
FULL-CASED UPFLOW/COUNTERFLOW FOR
COOLING/HEAT PUMPS
MODELS: FC
PARTIAL-CASED UPFLOW FOR COOLING/HEAT PUMP
MODELS: PC
ISO 9001
Certified Quality
Management System
INSTALLATION MANUAL
LIST OF SECTIONS
SAFETY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
GENERAL INFORMATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
COIL METERING DEVICES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
COIL INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
DUCT CONNECTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
CONDENSATE DRAIN CONNECTIONS . . . . . . . . . . . . . . . . . . . . . . 6
REFRIGERANT LINE CONNECTION . . . . . . . . . . . . . . . . . . . . . . . . 7
COIL CLEANING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
AIR SYSTEM ADJUSTMENT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
INSTALLATION VERIFICATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
LIST OF FIGURES
Component Location - Coil MC & FC . . . . . . . . . . . . . . . . . . . . . . . . . .2
Component Location - Coil PC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
TXV Bulb Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
Proper Bulb Location . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
Duct Flanges - Coil FC/MC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
Vertical Applications with Furnaces . . . . . . . . . . . . . . . . . . . . . . . . . . .5
Horizontal Right Application with Furnaces . . . . . . . . . . . . . . . . . . . . .5
Horizontal Left Application with Furnaces . . . . . . . . . . . . . . . . . . . . . .5
Upflow - PC Coil Installation with Furnace . . . . . . . . . . . . . . . . . . . . . 5
Condensate Deflector on Vertical Drain Pan . . . . . . . . . . . . . . . . . . . 6
Condensate Deflector on Horizontal Drain Pan Edge . . . . . . . . . . . . . 6
S-Clip Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Pressure Check . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
TXV Check List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Drain Traps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Location of Trapped and Plugged Drain Connections . . . . . . . . . . . . 8
LIST OF TABLES
Dimensions - MC Coils . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
Dimensions - FC Coils . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
Dimensions - PC Coils . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
Coil Air Flow Limits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Coil Projection Dimensions - PC Coils . . . . . . . . . . . . . . . . . . . . . . . . 5
Air Flow Data - Static Pressure Drop . . . . . . . . . . . . . . . . . . . . . . . . . 7
SECTION I: SAFETY
This is a safety alert symbol. When you see this symbol on
labels or in manuals, be alert to the potential for personal
injury.
Understand and pay particular attention to the signal words DANGER,
WARNING, or CAUTION.
DANGER indicates an imminently hazardous situation, which, if not
avoided, will result in death or serious injury.
WARNING indicates a potentially hazardous situation, which, if not
avoided, could result in death or serious injury.
CAUTION indicated a potentially hazardous situation, which, if not
avoided may result in minor or moderate injury. It is also used to alert
against unsafe practices and hazards involving only property damage.
WARNING
Improper installation may create a condition where the operation of
the product could cause personal injury or property damage.
Improper installation, adjustment, alteration, service or maintenance
can cause injury or property damage. Refer to this manual for assis-
tance or additional information, consult a qualified installer or service
agency.
!
CAUTION
This product must be installed in strict compliance with the enclosed
installation instructions and any applicable local, state, and national
codes including, but not limited to building, electrical, and mechanical
codes.
WARNING
The furnace area must not be used as a broom closet or for any other
storage purposes, as a fire hazard may be created. Never store items
such as the following on, near or in contact with the furnace.
1. Spray or aerosol cans, rags, brooms, dust mops, vacuum
cleaners or other cleaning tools.
2. Soap powders, bleaches, waxes or other Cleaning com-
pounds; plastic items or containers; gasoline, kerosene, ciga-
rette lighter fluid, dry cleaning fluids or other volatile fluid.
3. Paint thinners and other painting compounds.
4. Paper bags, boxes or other paper products
Never operate the furnace with the blower door removed. To do so
could result in serious personal injury and/or equipment damage.
!
!
Question and Answer IconNeed help?

Do you have a question about the York FC60C and is the answer not in the manual?

York FC60C Specifications

General IconGeneral
BrandYork
ModelFC60C
CategoryHeat Pump
LanguageEnglish

Summary

GENERAL INFORMATION

INSPECTION

Inspect the coil for damage during transit and check the drain pan for cracks or breakage.

CLEARANCES

Ensure adequate space for refrigerant piping, maintenance, servicing, condensate drain line, and filter removal.

COIL METERING DEVICES

TXV Bulb Installation

Guidance on installing the TXV bulb correctly, including its location and insulation for accurate temperature sensing.

Proper Bulb Location

Details on the correct positioning of the TXV bulb for accurate temperature sensing on the suction line.

COIL INSTALLATION

DUCT FLANGES

Instructions for preparing and using the duct flanges for connecting ductwork to the coil.

Vertical Applications with Furnaces

Steps for installing the coil in upflow or downflow configurations with furnaces, including duct connections.

Horizontal Applications

Procedures for installing MC model coils in a horizontal orientation with furnace or air handler.

FURNACE ASSEMBLY - PC

Specific instructions for installing PC coils on top of upflow furnaces, including ductwork and air leakage.

DUCT CONNECTIONS

CRITICAL COIL PROJECTION

Maintain minimum distance between coil top and duct top for proper air flow and installation.

CONDENSATE DRAIN CONNECTIONS

SUCTION FEEDER TUBE CONDENSATE DEFLECTOR

Instructions for positioning the condensate deflector for proper water drainage into the drain pan.

REFRIGERANT LINE CONNECTION

COIL CLEANING

AIR SYSTEM ADJUSTMENT

INSTALLATION VERIFICATION

Is coil metering device installed correctly?

Check if the correct TXV is installed and the TXV bulb is positioned and insulated correctly.

Were the primary and secondary drains trapped correctly?

Verify that the primary and secondary drain lines are trapped or plugged as required.

Were all drains trapped or plugged?

Confirm that all appropriate drain connections are trapped or plugged according to installation requirements.