TECHNICAL GUIDE
STELLAR PLUS ECO
2 TM
SPLIT-SYSTEM AIR CONDITIONERS
R-410A 12 SEER
MODELS:
H4AH024 THRU 060
(2 THRU 5 NOMINAL TONS)
Due to continuous product improvement, specifications
are subject to change without notice.
Visit us on the web at www.york.com for the most
up-to-date technical information.
Additional rating information can be found at
www.ari.org.
R
N
E
M
P
I
U
Q
E
T
Y
R
A
T
I
N
U
0
1
2
A
R
I
R
A
D
N
A
T
S
D
I
S
N
O
T
C
E
S
F
O
C
C
I
F
I
T
R
E
N
O
I
T
A
H
T
I
W
C
G
N
I
Y
L
P
M
O
S
A
I
R
A
O
T
D
E
I
F
I
T
R
E
C
R
E
R
U
T
C
A
F
U
N
A
M
C
-
G
N
I
N
O
I
T
I
D
N
O
R
I
A
CERTIFICATION APPLIES ONLY
WHEN THE COMPLETE
SYSTEM IS LISTED
WITH ARI.
LISTED
036-21215-003 Rev. B (1202)
FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE
DESCRIPTION
The HAH Series condensing unit is the outdoor part of a ver-
satile system of air conditioning. It is designed to be custom-
matched with one of York’s complete line of evaporator sec-
tions, each designed to serve a specific function. Matching
Air Handlers are available for upflow, downflow or horizontal
application to provide a complete system. Electric heaters are
available if required. Add-On coils are available for use with
upflow, downflow or horizontal furnaces.
WARRANTY
5-year limited parts warranty.
10-year limited compressor warranty.
FEATURES
QUALITY CONDENSER COILS - The coil is constructed
of copper tube and hardened black coated aluminum fins
for durability and long lasting efficient operation. The fins
on the unit are protected with a decorative grille.
PROTECTED COMPRESSOR - The compressor is inter-
nally protected against high pressure and temperature.
This is accomplished by the simultaneous operation of
high pressure relief valve and a temperature sensor which
protects the compressor if undesirable operating condi-
tions occur. Additionally the unit has high and low pressure
switch for extra protection against high pressure or loss of
charge. The compressor is protected by a 10 year limited
warranty.
DURABLE FINISH - Cabinet is made of powder painted
steel over prepainted primer. The pre-treated flat galva-
nized steel provides a better paint to steel bond, which
resists corrosion and rust creep. Special primer formulas
and champagne finish insure less fading when exposed to
sunlight. This finish has been tested to provide 1/3 greater
protection than conventional units.
LOWER INSTALLED COST - Installation time and costs
are reduced by easy power and control wiring connec-
tions. Hard start kits are available for non-scroll models. All
units contain enough refrigerant for a matching indoor coil
and 15 feet of interconnecting piping. The small base
dimension means less space is required on the ground or
roof.
TOP DISCHARGE - The warm air from the top mounted
fan is blown up away from the structure and any landscap-
ing. This allows compact location on multi-unit applica-
tions.
LOW OPERATING SOUND LEVEL - The upward air flow
carries the normal operating noise up away from the living
area. The rigid top panel effectively isolates any motor
sound. Isolator mounted compressor and the rippled fins
of the condenser coil muffle the normal fan motor and
compressor operating sounds.
LOW MAINTENANCE - Long life permanently lubricated
motor bearings need no annual servicing.
EASY SERVICE ACCESS - Fully exposed refrigerant con-
nections and a single panel covering the electrical controls
make servicing easy.
SECURED SERVICE VALVES -Provided on both the liq-
uid and vapor sweat connections for ease of evacuating
and charging.
U.L. and C.U.L. listed - approved for outdoor application.
Certified in accordance with the Unitary Small Equipment cer-
tification program, which is based on ARI Standard 210/240.
Question and Answer IconNeed help?

Do you have a question about the York H4AH030S06 and is the answer not in the manual?

York H4AH030S06 Specifications

General IconGeneral
BrandYork
ModelH4AH030S06
CategoryAir Conditioner
LanguageEnglish

Summary

TECHNICAL GUIDE

DESCRIPTION

Overview of the HAH Series condensing unit and its system integration.

WARRANTY

Details the limited warranty coverage for parts and the compressor.

FEATURES

Highlights key attributes like coil quality, compressor protection, and finish.

Physical and Electrical Data

MODEL

Lists the specific HAH Series split-system air conditioner models covered.

DIMENSIONS

Provides physical dimensions and connection sizes for different unit models.

R-410A SYSTEM CHARGING PROCEDURE

ADDITIONAL R-410A CHARGE / ORIFICE SIZE

Specifies charging details and orifice sizes for matched systems.

REFRIGERANT LINE ADDER OZ./FT.

Indicates the refrigerant addition per foot of tubing.

COOLING CAPACITY - With Air Handler Coils

1 PH 12 SEER AC WITH N1AH / G2FD

Cooling data for 1-phase 12 SEER AC with N1AH/G2FD coils.

1 PH 12 SEER AC / N1VS - VARIABLE SPEED

Cooling data for 1-phase 12 SEER AC with N1VS variable speed.

1 PH 12 SEER AC / F2RP / RC / FP / FC / FV

Cooling data for specific F2RP/RC/FP/FC/FV coils.

COOLING CAPACITY - Upflow, Downflow, & Horizontal Furnaces and Coils

H4AH024S06 Furnace Coil Data

Cooling capacity for H4AH024S06 with furnace/coil combinations.

H4AH030S06 Furnace Coil Data

Cooling capacity for H4AH030S06 with furnace/coil combinations.

H4AH036S06 Furnace Coil Data

Cooling capacity for H4AH036S06 with furnace/coil combinations.

COOLING CAPACITY - With Variable Speed Furnaces

H4AH024S06 Variable Speed Data

Cooling capacity for H4AH024S06 with variable speed furnaces.

H4AH030S06 Variable Speed Data

Cooling capacity for H4AH030S06 with variable speed furnaces.

H4AH036S06 Variable Speed Data

Cooling capacity for H4AH036S06 with variable speed furnaces.

H4AH042S06 Variable Speed Data

Cooling capacity for H4AH042S06 with variable speed furnaces.

COOLING CAPACITY - With Variable Speed Furnaces (Continued)

H4AH042S06 Continued Data

Continued cooling capacity for H4AH042S06 with variable speed.

H4AH048S06 Variable Speed Data

Cooling capacity for H4AH048S06 with variable speed furnaces.

H4AH060S06 Variable Speed Data

Cooling capacity for H4AH060S06 with variable speed furnaces.

ACCESSORIES

Hard Start Kit

Accessory to improve starting torque in low voltage areas.

Compressor Blanket

Accessory to reduce compressor operating sound.

Off Cycle Timer Delay

Accessory to prevent rapid compressor cycling.

Room Thermostats

Overview of compatible thermostat options.

SOUND RATINGS

DECIBELS

Sound ratings measured in decibels, with and without a blanket.

TYPICAL INSTALLATION

TYPICAL FIELD WIRING - 1 Phase Application

Diagram for field wiring a 1-phase unit.

COOLING PERFORMANCE DATA - HAH024S06

HAH024S06 Coil Performance Data

Cooling performance data for HAH024S06 with various indoor coils.

Performance Multipliers for HAH024S06

Factors to adjust performance for HAH024S06 indoor coils.

COOLING PERFORMANCE DATA - HAH030S06

HAH030S06 Coil Performance Data

Cooling performance data for HAH030S06 with various indoor coils.

Performance Multipliers for HAH030S06

Factors to adjust performance for HAH030S06 indoor coils.

COOLING PERFORMANCE DATA - HAH036S06

HAH036S06 Coil Performance Data

Cooling performance data for HAH036S06 with various indoor coils.

Performance Multipliers for HAH036S06

Factors to adjust performance for HAH036S06 indoor coils.

COOLING PERFORMANCE DATA - H4AH042S06

H4AH042S06 Coil Performance Data

Cooling performance data for HAH042S06 with various indoor coils.

Performance Multipliers for H4AH042S06

Factors to adjust performance for H4AH042S06 indoor coils.

COOLING PERFORMANCE DATA - HAH048S06

HAH048S06 Coil Performance Data

Cooling performance data for HAH048S06 with various indoor coils.

Performance Multipliers for HAH048S06

Factors to adjust performance for HAH048S06 indoor coils.

COOLING PERFORMANCE DATA - HAH060S06

HAH060S06 Coil Performance Data

Cooling performance data for HAH060S06 with various indoor coils.

Performance Multipliers for HAH060S06

Factors to adjust performance for HAH060S06 indoor coils.

MATCHING INDOOR COMPONENTS

ADD-ON COILS - FOR FURNACE APPLICATIONS

Illustrations of add-on coils for furnace applications.

AIR HANDLERS - FOR NON-FURNACE APPLICATIONS

Illustrations of air handlers for non-furnace use.

NOTES