036-21023-002 Rev. A (5/00)
Unitary Products Group 5
H4TS036
P1XUB12V055
P1DUB16V080
17
17
G1UA048S17
1 750 20.0 16.0 1.49 13.4
15.0
2 1150 34.8 26.0 3.08 11.3
G2FD036S17
1 750 20.0 16.0 1.49 13.4
15.0
2 1150 34.8 26.0 3.08 11.3
G2FD046S17
1 750 20.0 16.0 1.49 13.4
15.0
2 1150 34.8 26.0 3.08 11.3
P1XUC16V075 21
G1UA048S21
1 770 21.0 16.6 1.49 14.1
15.0
2 1185 36.8 27.0 3.17 11.6
G2FD036S21
1 770 20.4 16.0 1.50 13.6
15.0
2 1185 35.4 26.0 3.11 11.4
G2FD042S21
1 770 20.4 16.0 1.50 13.6
15.0
2 1185 35.4 26.0 3.11 11.4
G2FD048S21
1 770 21.0 16.6 1.49 14.1
15.5
2 1185 36.8 27.0 3.17 11.6
P1XUC20V095
P1DUC20V096
21
G1UA048S21
1 770 21.0 16.0 1.47 14.3
15.5
2 1200 37.0 27.0 3.19 11.6
G2FD036S21
1 770 20.4 16.4 1.49 13.7
15.0
2 1200 35.4 26.0 3.11 11.4
G2FD042S21
1 770 20.4 16.4 1.49 13.7
15.0
2 1200 35.4 26.0 3.11 11.4
G2FD048S21
1 770 21.0 16.6 1.48 14.2
15.5
2 1200 37.0 27.0 3.19 11.6
P1XUD20V112 24 G2FD048S24
1 770 21.0 16.6 1.48 14.2
15.5
2 1200 37.0 27.0 3.19 11.6
H4TS048
P1XUC16V075
P1XUC20V095
P1DUC20V096
21
G-UA048S21
1 1050 25.0 1.75 14.3
15.5
2 1600 49.0 36.0 4.54 10.8
G-UA060S21
1 1050 26.0 21.0 1.82 14.3
15.5
2 1600 51.0 37.5 4.72 10.8
G-FD048S21
1 1050 25.0 20.0 1.75 14.3
15.5
2 1600 49.0 36.0 4.54 10.8
P1XUD20V112 24
G-FD048S24
1 1050 25.0 20.0 1.75 14.3
15.5
2 1600 49.0 36.0 4.54 10.8
G-UA060S24
1 1050 26.0 21.0 1.82 14.3
15.5
2 1600 51.0 37.5 4.72 10.8
G-FD060S24
1 1050 26.0 21.0 1.82 14.3
15.5
2 1600 51.0 37.5 4.72 10.8
H4TS060
P1XUC20V095
P1DUC20V096
21 G-UA060S21
1 1250 33.0 26.4 2.52 13.1
14.5
2 1900 59.0 43.0 5.67 10.4
P1XUD20V112 24
G-UA060S24
1 1250 33.0 26.4 2.52 13.1
14.5
2 1900 59.0 43.0 5.67 10.4
G-FD060S24
1 1250 33.0 26.4 2.52 13.1
14.5
2 1900 59.0 43.0 5.67 10.4
G-FD061H24
1 1250 34.0 27.0 2.54 13.4
15.0
2 1900 60.0 44.0 5.66 10.6
1. Refer to coil installation guide for proper coil application.
2. Standard cooling operation is limited to 45°F outdoor ambient.
3. EER (Energy Efficiency Ratio) is the total cooling output in BTU’s at a 95°F outdoor ambient divided by the total electric power in
watt-hours at those conditions.
Certified in accordance with the Unitary Small Equipment certification program which is based on ARI Standard 210/240
MBH based on 80°F entering air temperature, 50% RH, and rated air flow
KW includes compressor, outdoor fan and indoor blower motor watts. Add-on coils include 365 watts/1000 CFM for blowr motor.
Table 3: COOLING CAPACITY - Variable Speed Furnace (Continued)
UNIT
MODEL
VARIABLE SPEED
FURNACE MODEL
W
COIL MODEL
1
COOLING
2
STAGE
RATED
CFM
CAP
SYSTEM
KW
EER
3
SEER
TOTAL SENS.