Units shall be constructed with a high pressure switch for system protection.
Units shall be constructed with all badging and labels applied at the factory.
Unit components
Compressor shall be hermetic with internal electrical overload protection and internal
overpressure protection.
Compressor shall be mounted on neoprene vibration isolators that do not require the removal
of transportation clips or brackets.
Outdoor fan shall be direct drive with horizontal air discharge for low sound levels.
Outdoor fan blades shall be swept-wing to minimize sound (applies to select models).
Outdoor fan motor shall be totally enclosed with permanently lubricated ball bearings motors
approved for vertical shaft applications.
Outdoor fan motor shall be ECM construction with permanently lubricated ball bearing motors
approved for vertical shaft applications.
Unit warranties
Unit manufacturer shall provide a 5-year compressor warranty without a requirement for unit
registration.
Typical installation
Figure 3:  Minimum clearances when selecting a location
CAUTION
Caution
Care must be taken to prevent ice from damaging the unit. Damage may occur from ice falling onto
unit from a sloped roof or from a vertical drip line due to a partial overhang.
13YORK Technical Guide: HMH7 Series - 17 SEER Horizontal Discharge Modulating Heat Pump