Loading...
700699-YTG-B-0812
6 Johnson Controls Unitary Products
— = Not applicable.
MA Modular Air Handlers use Coil Only Ratings.
TCGF42S41S3(E)
MV16C 21.0 FC60C 1400 40.5 30.6 15.50 12.75
MV20D 24.5 FC/MC48D 1400 42.0 31.4 15.50 13.00
MV20D 24.5 FC/MC60D 1400 41.5 31.4 15.50 13.00
MV20D 24.5 FC/MC62D 1400 42.0 31.4 16.00 13.00
MV20D 24.5 FC64D 1300 42.0 31.4 16.50 13.50
MX16C 21.0 FC/MC43C 1365 41.0 30.6 16.00 13.25
MX16C 21.0 FC/MC48C 1390 41.5 31.2 16.25 13.25
MX16C 21.0 FC60C 1420 40.5 30.8 16.00 13.00
MX20D 24.5 FC/MC48D 1415 41.5 31.2 16.00 13.25
MX20D 24.5 FC/MC60D 1470 41.0 31.6 16.25 13.25
MX20D 24.5 FC/MC62D 1470 41.5 32.2 16.25 13.50
MX20D 24.5 FC64D 1470 43.0 33.4 16.75 13.75
TCGF48S41S4(E)
AHE48D 24.5 1600 46.0 32.6 15.25 12.50
AHE60D 24.5 1565 46.5 33.2 15.75 13.00
AHR48D 24.5 1610 45.5 32.0 14.25 11.75
AHR60D 24.5 1620 46.5 33.0 14.50 12.25
AHV48D 24.5 1585 45.5 31.9 14.75 12.25
AHV60D 24.5 1570 46.0 32.4 15.00 12.50
AV*48 24.5 1625 46.0 32.4 15.00 12.50
AV*60 24.5 1560 46.0 32.6 15.25 12.50
MV16C 21.0 FC/MC48C 1625 45.0 33.2 15.00 12.25
MV16C 21.0 FC60C 1625 46.0 32.2 15.00 12.50
MV20D 24.5 FC/MC48D 1620 45.5 33.4 15.50 12.50
MV20D 24.5 FC/MC60D 1600 46.0 32.2 15.00 12.25
MV20D 24.5 FC/MC62D 1630 47.0 33.8 15.50 12.75
MV20D 24.5 FC64D 1630 47.5 34.2 16.00 13.00
MX16C 21.0 FC/MC48C 1685 45.5 34.0 15.25 12.25
MX16C 21.0 FC60C 1420 45.5 31.0 15.75 13.00
MX20D 24.5 FC/MC48D 1525 45.5 33.4 15.50 12.75
MX20D 24.5 FC/MC60D 1470 45.5 31.2 16.00 13.00
MX20D 24.5 FC/MC62D 1605 47.0 34.0 16.00 13.25
MX20D 24.5 FC64D 1605 47.5 34.4 16.50 13.50
TCGF60S41S4(E)
AHE60D 24.5 1835 56.5 39.6 14.50 12.50
AHR60D 24.5 1870 56.0 39.1 13.75 11.75
AHV60D 24.5 1635 55.5 37.4 14.25 12.00
AV*60 24.5 1730 55.5 37.4 14.50 12.00
MV20D 24.5 FC/MC60D 1845 56.0 38.1 14.50 12.25
MV20D 24.5 FC/MC62D 1855 56.5 39.6 14.25 12.25
MV20D 24.5 FC64D 1855 57.5 40.5 14.50 12.50
MX20D 24.5 FC/MC60D 1780 55.5 37.4 14.50 12.50
MX20D 24.5 FC/MC62D 1795 57.0 39.6 15.00 12.75
MX20D 24.5 FC64D 1795 57.5 41.0 15.25 13.00
Rated in accordance with DOE test procedures (Federal Register 12-27-79 and 3-18-88) and ANSI/AHRI Standard 210/240.
Cooling MBH based on 80°F entering air temperature, 50% RH (Relative Humidity), and rated air flow.
EER (Energy Efficiency Ratio) is the total cooling output in BTUs at 95°F outdoor ambient divided by the total electric power in watt-hours at those conditions.
SEER (Seasonal Energy Efficiency Ratio) is the total cooling output in BTUs during a normal annual usage period for cooling divided by the total electric power input in
watt-hours during the same period.
1. MC coils available with a factory installed horizontal drain pan. See price pages for specific model number.
COOLING CAPACITY - With Air Handler Coils (Continued)
UNIT
MODEL
AIR HANDLER
COIL
MODEL
1
COOLING
MODEL WIDTH
RATED
CFM
NET MBH
SEER EER
TOTAL SENS.
14.5 SEER AC WITH AIR HANDLERS